Fluke 1587FC Insulation Multimeter

The high-performance 2-in-1 insulation digital multimeter

This insulation multimeter is the combination of a digital insulation tester that comes supplied with a full-featured, True RMS digital multimeter in a single compact, handheld unit, which enables maximum versatility for troubleshooting and preventative maintenance.

Features Fluke 1587FC Insulation Multimeter

  • PI/DAR timed ratio tests
  • Live circuit detection prevents insulation test if voltage >30 V is detected for added user protection
  • VFD low-pass filter for accurate motor drive measurements
  • Auto-discharge of capacitive voltage for added user protection
  • Insulation test of 0.01 MΩ to 2 GΩ
  • Insulation test voltages of 50, 100, 250, 500 V for many applications
  • AC/DC voltage, DC millivolts, AC/DC milliamps, resistance (Ω), continuity
  • Capacitance, diode test, temperature, Min/Max, frequency (Hz)
  • Auto power off to save battery power
  • CAT III 1000 V, CAT IV 600 V measurement category
  • Large display with backlight
  • Safety first. Keep yourself out of harm’s way by monitoring your test measurements remotely
  • Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone
  • Quickly find problems by saving and comparing measurements over time on a wireless device

Keep yourself safe. Find hidden problems faster. Put the paperwork down.

Fluke Connect and this insulation multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily – all at a safe distance.

Add diagnostics with Fluke Connect

Fluke Connect is enabled so you can download the free application to your smartphone and gain additional functions, including:

  • Safety first. Keep yourself out of harm’s way by monitoring your test measurements remotely
  • Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone
  • Quickly find problems by saving and comparing measurements over time on a wireless device
  • PI/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems faster
  • Memory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over time
  • Temperature compensation to establish accurate baselines and relevant historical comparisons
  • Historical tracking and trending of assets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke Connect® Assets (sold separately)
  • Provides memory storage through Fluke Connect Measurements to eliminate the need to write down results
  • Includes live circuit detection to prevent insulation test if voltage >30 V is detected
  • Provides automated temperature compensation to establish accurate baselines
  • Incorporates VFD low-pass filter for accurate variable frequency motor drive measurements
  • Includes auto-discharge of capacitive voltage for added user protection
  • Measures AC/DC voltage, DC millivolts, AC/DC milliamps, resistance, and continuity
  • Includes capacitance, diode test, temperature, min/max, frequency measurements and insulation test smoothing reading

Specifications Fluke 1587FC Insulation Multimeter

AC Voltage Measurements
Range 600 mV
6 V
60 V
600 V
1000 V
Resolution 0.1 mV
0.001 V
0.01 V
0.1 V
1 V
50 to 60 Hz ±(% of Rdg + counts) ±(1% + 3)
±(1% + 3)
±(1% + 3)
±(1% + 3)
±(2% + 3)
60 to 5000 Hz ±(% of Rdg + counts) ±(2% + 3)
±(2% + 3)
±(2% + 3)
±(2% + 3)1
±(2% + 3)1
Low-Pass Filter Voltage
Range 600 mV
6 V
60 V
600 V
1000 V
Resolution 0.1 mV
0.001 V
0.01 V
0.1 V
1 V
50 to 60 Hz ±(% of Rdg + counts) ±(1% + 3)
±(1% + 3)
±(1% + 3)
±(1% + 3)
±(2% + 3)
60 to 400 Hz ±(% of Rdg + counts) ±(2% + 3) – (6% – 3)
±(2% + 3) – (6% – 3)
±(2% + 3) – (6% – 3)
±(2% + 3) – (6% – 3)
±(2% + 3) – (6% – 3)
DC Voltage Measurement
Range 6 V DC
60 V DC
600 V DC
1000 V DC
Resolution 0.001 V
0.01 V
0.1 V
1 V
Accuracy ±(% of Rdg + Counts) ±(0.09% + 2)
±(0.09% + 2)
±(0.09% + 2)
±(0.09% + 2)
Input Impedance 10 MΩ (nominal), <100 pF
Nominal Mode Rejection Ratio >60 dB at 50 or 60 Hz
Common Mode Rejection Ratio >120 dB at DC, 50 or 60 Hz (1 k unbalance)
DC Millivolts Measurement
Range 600 mV DC
Resolution 0.1 mV
Accuracy ±(% of Rdg + Counts) ±(0.1 + 1)
DC and AC Current Measurement
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)1
Burden Voltage (Typical) 2 mV/mA
Range 60 mA
Resolution 0.01 mA
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)1
Burden Voltage (Typical) 2 mV/mA
DC
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden Voltage (Typical) 2 mV/mA
Range 60 mA
Resolution 0.01 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden Voltage (Typical) 2 mV/mA
Overload 600 mA for 2 minutes maximum
Fuse Protection for mA Input 0.44 mA, 1000 V, IR 10 kA
AC Conversion Inputs are ac-coupled and calibrated to the RMS value of sine wave input
Ohms Measurement
Range 600 Ω
6 kΩ
60 kΩ
600 kΩ
6 MΩ
50 MΩ
Resolution 0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Accuracy +(% of Rdg+Counts)1 ±(0.9% + 2)
±(0.9% + 2)
±(0.9% + 2)
±(0.9% + 2)
±(0.9% + 2)
±(1.5% + 3)
Overload Protection 1000 RMS or DC
Open Circuit Test Voltage <8 V DC
Short Circuit Current <1.1 mA
Diode Test
Diode Test Indication Display voltage drop: 0.6 V at 1.0 mA nominal test current
Accuracy ±(2% + 3)
Continuity Test
Continuity Indication Continuous audible tone for test resistance below 25 Ω and off above 100 Ω
Maximum reading: 1000 Ω
Open Circuit Voltage <8.0 V
Short Circuit Current 1.0 mA typical
Overload Protection 1000 V RMS
Response Time >1 m sec
Frequency Measurement
Range 99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
Resolution 0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
Accuracy ±(% of Rdg+Counts) ±(0.1% + 1)
±(0.1% + 1)
±(0.1% + 1)
±(0.1% + 1)
Frequency Counter Sensitivity
600.0 mV AC V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 mV
V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 150.0 mV
DC Trigger Levels¹ to 20 kHz2: NA
6.0 V V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 1.0 V
V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 1.5 V
DC Trigger Levels¹ to 20 kHz2: -400.0 mV and 2.5 V
60.0 V V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 10.0 V
V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 36.0 V
DC Trigger Levels¹ to 20 kHz2: 1.2 V and 4.0 V
600.0 V V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 V
V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA
DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 V
1000.0 V V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 300.0 V
V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA
DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 V
Capacitance
Range 1000 nF
10.00 µF
100.0 µF
9999 µF
Resolution 1 nF
0.01 µF
0.1 µF
1 µF
Accuracy ±(% of Rdg+Counts) ±(1.2% + 2)
±(1.2% + 2)
±(1.2% ± 90 counts)
±(1.2% ± 90 counts)
Temperature Measurement
Range -40 to 998°F (-40 to 537°C)
Resolution 0.1°F (0.1°C)
Accuracy ±(% of Rdg+Counts)1 ±(1% + 10 counts)
±(1% + 18 counts)
Insulation Specifications
Measurement Range 0.01 MΩ to 2 GΩ
Test Voltages 50, 100, 250, 500, 1000 V
Test Voltage Accuracy 20%, 0%
Short-Circuit Test Current 1 mA nominal
Auto Discharge Discharge time <0.5 second for C=1 µF or less
Live Circuit Detection Inhibit test if terminal voltage >30 V prior to initialization of test
Maximum Capacitive Load Operable with up to 1 µF load
Output Voltage
50 V (0% to +20%) Display range: 0.01 to 6.00 MΩ
Resolution: 0.01 MΩ
Test current: 1 mA at 50 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
Display range: 6.0 to 50.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 50 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
100 V (0% to +20%) Display range: 0.01 to 6.00 MΩ
Resolution: 0.01 MΩ
Test current: 1 mA at 100 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
Display range: 6.0 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 100 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
Display range: 6.0 to 100.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 100 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
250 V (0% to +20%) Display range: 0.1 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 250 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 60 to 250 MΩ
Resolution: 1 MΩ
Test current: 1 mA at 250 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
500 V (0% to +20%) Display range: 0.1 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 500 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 60 to 500 MΩ
Resolution: 1 MΩ
Test current: 1 mA at 250 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
1000 V (0% to +20%) Display range: 0.1 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 1 MΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 60 to 600 MΩ
Resolution: 1 MΩ
Test current: 1 mA at 1 MΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 0.6 to 2.0 GΩ
Resolution: 100 MΩ
Test current: 1 mA at 1 MΩ
Resistance accuracy ±(% of Rdg + Counts): ±(10% + 3 counts)

 

Fluke 1587FC Insulation Multimeter Datasheet

 

 

Jual Fluke 1587FC Insulation Multimeter dengan harga murah dan berkualitas bergaransi tentunya. dapat di kirim ke seluruh wilayah Indonesia.

Jika anda butuh penawaran dan info Stok silahkan hubungi sales kami di No Telpon 0821 2742 8667 Telpon/SMS/Whatsapp.

Karyamandiritechindo.com Supplier dan Distributor Fluke di Indonesia. Karyamandiritechindo.com menyedikakan juga berbagai merk Alat ukur & Lab, Alat Survey, Alat komunikasi dan GPS

Dalam pengiriman produk yang pelanggan beli, sebelumnya sudah kami cek untuk memastikan produk dalam keadaan baik dan siap kirim.

Product Enquiry