Hanna HI-9829 Multiparameter pH/ISE/EC/DO/Turbidity Waterproof Meter with GPS option 

Meter with or without GPS

  • Built in GPS Receiver
  • 12 channel GPS receiver and antenna
  • Tracks location using satellites to within 30 feet
  • Latitude and longitude recorded with readings
  • Location naming for GPS coordinates
  • Distance from current location to stored location
  • HI-929829 software supplied integrates data collected with Google™ maps
  • Measurement readings including GPS coordinates
  • Date and time
  • Named locations and remarks
  • Sample number

(Google™ maps is a registered trademark of Google™, HANNA Instruments Ltd; has no affiliation with Google™).

Specifications:

HI-9829 specification with/without GPS

Temperature Compensation Automatic from -5 to 55°C
Models with GPS 12 Channel Receiver, 10m range
Logging memory from meter 44,000 records
Logging interval 1 second to 3 hours
Computer interface USB (with HI-929829)
FastTracker™ TAG ID Yes
Waterproof protection IP67
Environment 0 to 50°C, RH 100%
Power supply 1.5 V Alkaline C cells (4)/1.2V NiMH rechargeable C Cells (4) USB, 12V power adapter
Dimensions 221 x 115 x 55mm
Weight 750g
Maximum Probe Immersion Depth – 20 metres

HI-9829 parameter specifications

pH Range 0.00 to 14.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.02 pH
pH Calibration automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
mV Range ±600.0 mV
mV Resolution 0.1 mV
mV accuracy ±0.5 mV
ORP Range ±2000 mV
ORP Resolution 0.1 mV
ORP Accuracy ±1.0 mV
ORP Calibration automatic at one custom point (relative mV)
EC Range 0 to 200 mS/cm (absolute EC up to 400 mS/cm)
EC Resolution Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm, Automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm, Automatic (mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm
EC Accuracy ±1% of reading or ±1 µS/cm whichever is greater
EC Calibration automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
TDS Range 0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor)
TDS Resolution Manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L), Automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L), Automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L)
TDS Accuracy ±1% of reading or ±1 ppm (mg/L), whichever is greater
TDS Calibration based on conductivity or salinity calibration
Resistivity Range 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm
Resistivity Resolution dependent on resistivity reading
Resistivity Calibration based on conductivity calibration
Salinity Range 0.00 to 70.00 PSU
Salinity Resolution 0.01 PSU
Salinity Accuracy ±2% of reading or ±0.01 PSU whichever is greater
Salinity Calibration based on conductivity calibration
Seawater σ Range 0.0 to 50.0 σt, σ0, σ15
Seawater σ Resolution 0.1 σt, σ0, σ15
Seawater σ Accuracy ±1 σt, σ0, σ15
Seawater σ Calibration based on conductivity or salinity calibration
Ammonium-Nitrogen Range 0.02 to 200.0 ppm Am (as NH4 +-N)
Ammonium-Nitrogen Resolution 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm
Ammonium-Nitrogen Accuracy ±5 % reading or 2 ppm
Ammonium-Nitrogen Calibration 1 or 2 point, 10 ppm and 100 ppm
Chloride Range 0.6 to 200.0 ppm Cl (as Cl- )
Chloride Resolution 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm
Chloride Accuracy ±5 % of reading or 2 ppm
Chloride Calibration 1 or 2 point, 10 ppm and 100 ppm
Nitrate-Nitrogen Range 0.62 to 200.0 ppm Ni (as NO3 – -N)
Nitrate-Nitrogen Resolution 0.01 ppm to 1 ppm 0.1 ppm to 200 ppm
Nitrate-Nitrogen Accuracy ±5 % of reading or 2 ppm
Nitrate-Nitrogen Calibration 1 or 2 point, 10 ppm and 100 ppm
Turbidity Range 0.0 to 99.9 FNU; 100 to 1000 FNU
Turbidity Resolution 0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU
Turbidity Accuracy ±0.3 FNU or ±2 % of reading, whichever is greater
Turbidity Calibration Automatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom
DO Range 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)
DO Resolution 0.1%; 0.01 ppm (mg/L)
DO Accuracy 0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3% of reading
DO Calibration automatic one or two points at 0 and 100% or one custom point
Atmospheric Pressure Range 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
Atmospheric Pressure Resolution 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
Atmospheric Pressure Accuracy ±3 mm Hg within ±15°C from the temperature during calibration
Atmospheric Pressure Calibration automatic at one custom point
Ordering Information The HI-9829 is supplied with a HI-710140 hard carrying case, HI-7612VDC adapter, HI-7698292 probe maintenance kit, HI-929829 PC application software, HI-7698291 USB cable (PC to meter), HI-710045 power supply cable, HI-710046 cigarette lighter power cable, HI-9829-25 quick calibration solution, HI-920005 iButton with holder (5), HI-7609829-1 pH/ORP sensor, HI-7609829-2 galvanic DO sensor, HI-7609829-3 EC sensor, HI-7698290 short calibration beaker, HI-7698295 short protective weighted shield, NiMH rechargeable “C” cell batteries (4), 12VDC power adapter, and instruction manual.
Probes selected with turbidity option will include the HI-7609829-4 EC/turbidity sensor, HI-7698293 long calibration beaker and HI-7698296 long protective weighted shield in place of the EC sensor, short calibration beaker and short protective shield. Probes selected with turbidity option will also include turbidity calibration solutions (230 ml); HI-9829-16 0 FNU, HI-769829-17 20 FNU, and HI-9829-18 200 FNU.

Spare Solutions

HI-9829-10 25 sachets 10ppm ammonia-nitrogen calibration solution
HI-9829-10/11 10 sachets each of 10ppm and 100ppm ammonia-nitrogen calibration solution
HI-9829-11 25 sachets 100ppm ammonia-nitrogen calibration solution
HI-9829-12 25 sachets 10ppm chloride calibration solution
HI-9829-12/13 10 sachets each of 10ppm and 100ppm chloride calibration solution
HI-9829-13 25 sachets 100ppm chloride calibration solution
HI-9829-14 25 sachets 10ppm nitrate-nitrogen calibration solution
HI-9829-14/15 10 sachets each of 10ppm and 100pm nitrate-nitrogen calibration solution
HI-9829-15 25 sachets 100ppm nitrate-nitrogen calibration solution

 

Karyamandiritechindo.com menghadirkan ragam pilihan produk untuk Solusi Semua Jenis Pungukuran & Pengujian kebutuhan anda. Dengan menggabungkan surveyor, laboratorium, alat ukur instrument, tools, security, GPS, binocular dan alat sipil ke dalam satu website, Karyamandiritechindo siap memenuhi segala kebutuhan Anda. Karyamandiritechindo juga menawarkan pengalaman belanja yang dapat disesuaikan dengan kebutuhan. Anda dapat mengambil pesanan Anda ataupun dikirimkan ke alamat tujuan. Karyamandiritechindo.com – No.1 Home, E-Commerce in Indonesia

Jual Hanna HI-9829 Multiparameter pH/ISE/EC/DO/Turbidity Waterproof Meter with GPS option harga kompetitif Tentunya Gratis antar untuk Area Jakarta dan dapat dikirim keseluruh Indonesia, Jika Anda butuh bantuan silahkan hubungi Customer Service (026) 5540 5390 & Whatsapp di 0813-1864-0412 dan Email karyamandiritechindo@gmail.com