Product Description
Lutron TM-946 Thermometer 4 Channels
Thermometer TM-946 4 Channels Thermometer with 4 display locations at the same time to compare temperature values , auto and manual data logging functions.
Features Lutron TM-946 Thermometer 4 Channels :
- Type K/J, Pt 100 ohm, measurement with 4 display
- Show 4 channels display on the LCD at the same time
- Type K : -199.9° to 1370° C
- Type J : -199.9° to 1210° F
- PT 100 ohm : -199.9° to 850° C
- °C / °F, 0.1 degree / 1 degree
- 4 channels ( T1, T2, T3, T4 ), T1-T2
- Microcomputer circuit provides intelligent function and high accuracy
- Manual and auto data logger, with flexible sampling time selection, can save max. 16,000 reading data
- Records Maximum and Minimum readings with recall
- Data hold function for freezing the desired value
- Offset adjustment for the Type K and Type J measurement
- Offset adjustment for the PT 100 measurement
- Measuring unit can select to °C or °F
- DC 1.5V (UM-4, AAA) battery x 6 PCs
- Build in the input socket for DC 9V power adapter
- RS232 PC serial interface
- Few panel buttons, easy operation
- Built-in low battery indicator
- Heavy duty & compact housing case
Specifications Lutron TM-946 Thermometer 4 Channels :
Circuit | Custom one-chip of microprocessor LSI circuit. |
Display | LCD size : 52 mm x 38 mm * Show 4 channels display on the display at the same time. |
Display Unit | ℃ ,℉ |
Resolution | 0.1 , 0.1 ℉. |
Channels | T1, T2, T3, T4, T1-T2. |
Sensor type
|
Type K thermocouple probe. |
Type J thermocouple probe. | |
PT 100 ohm probe * Cooperate with an 0.00385 alpha coefficient, meet DIN IEC 751. |
|
Sampling Time of Data Logger
|
Manual : Push the data logger button once will save data one time. * Set the sampling to 0 second |
Auto : 1 second to 59 minutes and 59 seconds | |
Data Logger number
|
Max. 16,000-point Data logger |
Type K, Type J, 4 channels ( T1, T2, T3, T4 ) * Memory use 4 data point space in the memory |
|
Pt 100 ohm, 2 channels ( T1,T2 ) * Memory use 2 data point space in the memory |
|
T1-T2 * Memory use 4 data point space in the memory |
|
Temperature Compensation | Automatic temp. compensation for the cold junction both type K/J thermometer |
Linear Compensation | Linear Compensation for the full range. |
Offset, Span Adjustment | Available for advanced calibration procedure. |
Probe Input Socket
|
Type K, Type J : 2 pin thermocouple socket. |
Pt 100 ohm : Ear phone socket. | |
Accessories included | Instruction manual 1 PC Battery AAA ( 1.5 Volt ) 6 pcs |
Optional Accessories | Battery AAA ( 1.5 Volt ) 6 pcs Type K thermocouple probe. TP-01, TP-02A. TP-03, TP-04 Pt 100 ohm probe, TP-101. AC to DC 9V adapter. RS232 cable, UPCB-02. USB cable, USB-01 Data Acquisition software, SW-U801 Data Logger software, SW-DL2005. Soft carrying case, CA-05A. Hard carrying case, CA-06. |
ELECTRICAL SPECIFICATIONS
Type K, Type J thermocouple
Type K, Type J thermocouple | |||
Sensor Type | Resolution | Range | Accuracy |
Type K
|
1 ℃ | 1000 to 1370.0 ℃ |
± ( 0.5 % + 1 )
|
0.1 ℃ | -199.9 to 999.9 ℃ | ||
1 ℉ | 1000 to 2498 ℉ |
± ( 0.5 % + 1.8 )
|
|
0.1 ℉ | -199.9 to 999.9 ℉ | ||
Type J
|
1 ℃ | 1000 to 1210 ℃ |
± ( 0.5 % + 1 )
|
0.1 ℃ | -199.9 to 999.9 ℃ | ||
1 ℉ | 1000 to 2210 ℉ |
± ( 0.5 % + 1.8 )
|
|
0.1 ℉ | -199.9 to 999.9 ℉ |
PT 100 ohm | ||
Resolution | Range | Accuracy |
0.1 ℃ | -199.9 to 850 ℃ | ± ( 0.4 % + 1 ) |
1 ℉ | 1000 to 1562 ℉ |
± ( 0.4 % + 1.8 )
|
0.1 ℉ | -199.9 to 999.9 ℉ | |
1 ℉ | -200 to -327 ℉ | |
* Pt 100 ohm probe TP-101 is the optional accessory |
Lutron TM-946 – Data Sheet