Hanna HI-5221 Laboratory Research Grade Benchtop

Category Brand

Hanna HI-5221 Laboratory Research Grade Benchtop

The HI5221 is an advanced research grade benchtop pH/mV meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity. The HI5221 features a universal BNC connection for use with the expansive line of pH and ORP electrodes that Hanna Instruments offers. The meter is supplied with the HI1131B glass body, double junction, combination pH electrode that operates over a wide temperature range from 0 to 100°C.

Product Description

Hanna HI-5221 Laboratory Research Grade Benchtop pH/mV Meter with 0.001 pH Resolution

Karya Mandiri Techindo has a wide range of Hanna products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..

The HI5221 is an advanced research grade benchtop pH/mV meter that is completely customizable with a large color LCD, capacitive touch keys, and USB port for computer connectivity.

The HI5221 features a universal BNC connection for use with the expansive line of pH and ORP electrodes that Hanna Instruments offers. The meter is supplied with the HI1131B glass body, double junction, combination pH electrode that operates over a wide temperature range from 0 to 100°C.  All readings are automatically compensated for temperature variations with the separate HI7662-T temperature probe that is included.

The HI5221 can be calibrated up to five points with a choice of eight preprogrammed buffers or five custom buffers. The HI5221 features Hanna’s exclusive CAL Check™ to alert the user of potential problems during the pH calibration process such as “Electrode Dirty/Broken” and “Buffer Contaminated.” The overall probe condition based on the offset and slope characteristic of the electrode is displayed as a percentage after calibration is complete. The calibration data including date, time, buffers used, offset and slope can be accessed at any time along with the current measurement by selecting the Good Laboratory Practice (GLP) display option.

Three selectable logging modes are available: automatic, manual and AutoHold logging. Up to 100,000 data points can be recorded in 100 lots with 50,000 records max/lot and exported to a computer for data review and storage.

Features at-a-glance

Highly Customizable User Interface – The user interface of the HI5221 allows the user to show measurements in various modes: basic measurement with or without GLP information, real-time graphing, and logging data. Calibration stability criteria can be adjusted from fast, moderate, and accurate. Programmable alarm limits can be set to inside or outside allowable limits.

Color Graphic LCD– The HI5221 features a color graphic LCD with on-screen help, graphic, and custom color configurations. The display allows for real-time graphing and the use of virtual keys provide for an intuitive user interface.

Capacitive Touch – The HI5221 features sensitive capacitive touch buttons for accurate keystrokes when navigating menus and screens. There are four dedicated keys that are used for routine operations including calibration and switching measurement modes and four virtual keys that change based upon use. The capacitive touch technology ensures the buttons never get clogged with sample residue.

Choice of Calibration – Automatic buffer recognition, semiautomatic, and direct manual entry pH calibration options are available for calibrating up to five points, from a selection of eight standard buffers and up to five custom buffers.

GLP Data – HI5221 includes a GLP Feature that allows users to view calibration data and calibration expiration information at the touch of a key. Calibration data include date, time, buffers /standards used for calibration and slope characteristics. The offset is also displayed for pH electrodes.

CAL Check™ – CAL Check™alerts users to potential problems during the calibration of the pH electrode. Indicators include “Electrode Dirty/Broken,” “Buffer Contaminated,” electrode response time and the overall probe condition as a percentage that is based on the offset and slope characteristics.

Data Logging – Three selectable logging modes are available on the HI5221: automatic, manual, and AutoHold logging. Automatic and manual logs up to 100 lots with 50,000 records max/lot, with up to 100,000 total data points. Automatic logging features the option to save data according to sampling period and interval.

Data Transfer – Data can be transferred to a PC with USB cable and HI92000 software (both sold separately).

Contextual Help – Contextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration.  The help information displayed is relative to the setting/option being viewed.

CAL check

CAL Check Feature

GLP

Comprehensive GLP Data

Logging

Real-Time Logging

Specifications Hanna HI-5221 Laboratory Research Grade Benchtop

 
SKU HI5221-02
Product Name Laboratory Research Grade Benchtop pH/mV Meter with 0.001 pH Resolution – HI5221
Quote Required Yes
pH Range -2.0 to 20.0 pH, -2.00 to 20.00 pH, -2.000 to 20.000 pH
pH Resolution 0.1, 0.01, 0.001 pH
pH Accuracy ±0.1 pH, ±0.01 pH, ±0.002 pH ±1 LSD
pH Calibration automatic, up to five point calibration, eight standard buffers available (1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01,12.45) and five custom buffers
pH Temperature Compensation automatic or manual from -20.0 to 120.0 °C
pH CAL Check (electrode diagnostics) Yes
mV Range ±2000 mV
mV Resolution 0.1 mV
mV Accuracy ±0.2 mV ±1 LSD
mV Relative Offset ±2000 mV
Temperature Range -20.0 to 120.0 ºC, -4.0 to 248.0 °F, 253.15 to 393.15 K
Temperature Resolution 0.1 °C, 0.1 °F, 0.1 K
Temperature Accuracy ±0.2 °C, ±0.4 °F, ±0.2 K
Input Channels 1 – pH/ORP
pH Electrode HI1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included)
Temperature Probe HI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included)
Logging Type automatic, manual, AutoHold
Logging Memory record
Logging Interval settable between 1 second and 180 minutes max log time
Connectivity USB
GLP calibration data including date, time, buffers used, offset and slope
Display color graphic LCD with on-screen help, graphing, and custom color configuration
Power Supply 230VAC to 12 VDC adapter (included)
Environment 0 to 50°C (32 to 122°F; 273 to 323 K), RH max 95% non-condensing
Dimensions 160 x 231 x 94 mm (6.3 x 9.1 x 3.7”)
Weight 1.2 kg (2.64 lbs.)
Ordering Information HI5221 is supplied with HI1131B pH electrode, HI7662-T temperature probe, HI76404W electrode holder, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI700601 electrode cleaning solution sachet (2), HI7082 3.5M KCl electrolyte solution (30 mL), 12 VDC adapter and instructions.

 


Hanna HI-5221 – Manual


Produk asli Kami distributor langsung Hanna . Harga murah dan berkualitas bergaransi tentunya. dapat di kirim ke seluruh wilayah indonesia.

Dalam pengiriman produk yang pelanggan beli, sebelumnya sudah kami cek untuk memastikan produk dalam keadaan baik dan siap kirim.


 

Additional Information

Brand

Hanna

Model

HI-5221

Made In

Romania

Weight

1,5 kg

Product Enquiry

TESTIMONI PELANGGAN

alhamdulillah pesanan sudah sampai di Bengkulu. Pengalaman order di karyamandiritechindo.com Respon cepat. Pengiriman Cepat dan Free, Aman & Terpercaya.

Ibu Natalia Dan Ria
PT. AGricinal

Terimakasih karyamandiritechindo.com, orderannya sudah sampai dengan selamat Kurir Syariftama Express sangat ramah

PT. Bumi Bangun Perkasa
Ibu Rizeki

Order yg kedua, seperti biasa produk sangat memuaskan dan pelayannya ramah, Terimakasih Pak Aji Amanda Semoga di orderan berikutnya tetap TOP

PT. Daruna

Puas banget belanja di karyamandiritechindo.com. pengiriman cepat kualitas produk mantap.

PT. Niaga Andalan Serayat

BUAT PERMINTAAN HARGA