Hanna HI-83399-02 Water & Wastewater Multiparameter

Hanna HI-83399-02 Water & Wastewater Multiparameter

HI83399 benchtop photometer measures 40 different key water and wastewater quality parameters using 73 different methods that allow for multiple ranges and variations in chemistry for specific applications. The Chemical Oxygen Demand (COD) parameter is included for industrial and municipal wastewater treatment. The Phosphorous and Nitrogen parameters included are beneficial to municipal wastewater treatment customers that need to monitor their biological and chemical nutrient removal process.

Product Description

Hanna HI-83399-02 Water & Wastewater Multiparameter (with COD) Photometer and pH Meter

Karya Mandiri Techindo has a wide range of Hanna products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..

HI83399 benchtop photometer measures 40 different key water and wastewater quality parameters using 73 different methods that allow for multiple ranges and variations in chemistry for specific applications. The Chemical Oxygen Demand (COD) parameter is included for industrial and municipal wastewater treatment. The Phosphorous and Nitrogen parameters included are beneficial to municipal wastewater treatment customers that need to monitor their biological and chemical nutrient removal process. This photometer features an innovative optical system that uses LEDS, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source ensures accurate and repeatable photometric readings every time.

A digital pH electrode input is provided allowing the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.

Two USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.

The HI83399 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the 5 wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for education to teach the concept of absorbance by using the Beer-Lambert Law.

Features/Benefits

Backlit 128 x 64 Pixel Graphic LCD Display

  • Backlit graphic display allows for easy viewing in low light conditions
  • The 128 x 64 Pixel LCD allows for a simplified user interface with virtual keys  and on-screen help to guide the user through use of the meter

Built-in Reaction Timer for Photometric Measurements

  • The measurement is taken after the countdown timer expires.
  • Countdown timer ensures that all readings are taken at the appropriate reaction intervals regardless of user for better consistency in measurements

Absorbance mode

  • Hanna’s exclusive CAL Check cuvettes for validation of light source and detector
  • Allows for the user to plot concentration versus absorbance for a specific wavelength for use with user supplied chemistry or for teaching principles of photometry

Units of Measure

  • Appropriate unit of measure along with chemical form is displayed along with reading

Result Conversion

  • Automatically convert readings to other chemical forms with the touch of a button

Cuvette Cover

  • Aids in preventing stray light from affecting measurements

Digital pH Electrode Input

  • Measure pH and temperature with a single probe
  • Good Laboratory Practice (GLP) to track calibration information including date, time, buffers used, offset and slope for traceability
  • pH CAL Check alerts user to potential problems during the calibration process
  • Space saving having a pH meter and photometer built into one meter

Data Logging

  • Up to 1000 photometric and pH readings can be stored by simply pressing the dedicated LOG button. Logged readings are just as easily recalled by pressing the RCL button
  • Sample ID and User ID information can be added to a logged reading using alphanumeric keypad

Connectivity

  • Logged readings can be quickly and easily transferred to a flash drive using the USB-A host port or to a computer using the micro USB-B port
  • Data is exported as a .CSV file for use with common spreadsheet programs

Battery Status Indicator

  • Indicates the amount of battery life left

Error Messages

  • Photometric error messages include no cap, high zero, and standard too low
  • pH calibration messages include clean electrode, check buffer and check probe

On-screen Features

method selection

Method Selection

Users can easily select any one of the 60 measurement methods via the dedicated METHOD button.

data logging

Data Logging

Up to 1000 measurement readings can be logged with user and sample ID and recalled for future use.

ph measurement mode

pH Measurement Mode

Selecting the pH measurement mode allows for the photometer to be used as a professional pH meter with many features including temperature compensated measurements, automatic two point calibration, and GLP.

Digestion Parameters Features

HI83399 cuvette adapter

Cuvette Adapter

The HI83399 is supplied with a 16 mm cuvette adapter that accepts digestion vials.

COD reagents

Digestion Vial Methods

Compatible with COD (EPA, ISO, and mercury free methods), Nitrogen and Phosphorous reagetns packaged in 16 mm digestion vial. Reagents are sold separately.

HI839800 COD reactor

COD Reactor for Digestion Vials

A COD reactor is used to heat the digestion vials. The digestion vials must be heated to a specific temperature for a period time making the HI839800 an important accessory required to have a complete wastewater treatment monitoring system.

Advanced Optical System

HI83300 is designed with an innovative optical system that incorporates a beam splitter so that light can be used for absorbance readings and for a reference detector. The reference detector monitors the intensity of light and modulates when there is drift due to power fluctuation or the heating of the optical components. Each part has an important role in providing unparalleled performance from a photometer.

 

photometer multiparameter optical

High Efficiency LED Light Source

An LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components an electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue/violet light output.

High Quality Narrow Band Interference Filters

The narrow band interference filter not only ensure greater wavelength accuracy (+/- 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.

Reference Detector for a Stable Light Source

A beam splitter is used as part of the internal reference system of the HI83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.

Large Cuvette Size

The sample cell of the HI83300 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.

Focusing Lens for Greater Light Yield

Adding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.

Specifications Hanna HI-83399-02 Water & Wastewater Multiparameter

 
SKUHI83399-02
Product NameWater & Wastewater Multiparameter (with COD) Photometer and pH meter – HI83399
Quote RequiredYes
pH RangePhotometer
pH ResolutionPhotometer
pH AccuracyPhotometer
pH CalibrationAutomatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)
pH Temperature CompensationAutomatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used
pH CAL Check (electrode diagnostics)clean electrode and check buffer/check probe displayed during calibration
pH MethodPhotometer
pH-mV Range±1000 mV
pH-mV Resolution0.1 mV
pH-mV Accuracy±0.2 mV
Dissolved Oxygen Range0.0 to 10.0 mg/L (as O2)
Dissolved Oxygen Resolution0.1 mg/L
Dissolved Oxygen Accuracy±0.4 mg/L ±3% of reading
Dissolved Oxygen Measurement MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method
Absorbance Range0.000 to 4.000 Abs
Absorbance Resolution0.001 Abs
Absorbance Accuracy+/-0.003Abs @ 1.000 Abs
Alkalinity RangeFreshwater
Alkalinity Resolution1 mg/L
Alkalinity Accuracy±5 mg/L ±5% of reading
Alkalinity MethodColorimetric method
Aluminum Range0.00 to 1.00 mg/L (as Al3+)
Aluminum Resolution0.01 mg/L
Aluminum Accuracy±0.04 mg/L ±4% of reading
Aluminum MethodAdaptation of the aluminon method
Ammonia RangeLow Range
Ammonia ResolutionLow and Medium Range
Ammonia AccuracyLow Range
Ammonia MethodAdaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method
Anionic Surfactants Range0.00 to 3.50 mg/L (as SDBS)
Anionic Surfactants Resolution0.01 mg/L
Anionic Surfactants Accuracy±0.04 mg/L ±3% of reading
Anionic Surfactants MethodAdaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS
Bromine Range0.00 to 8.00 mg/L (as Br2)
Bromine Resolution0.01 mg/L
Bromine Accuracy±0.08 mg/L ±3% of reading
Bromine MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method.
Calcium RangeFreshwater
Calcium Resolution1 mg/L
Calcium AccuracyFreshwater
Calcium MethodFreshwater
Chemical Oxygen Demand RangeLow Range
Chemical Oxygen Demand Resolution1 mg/L
Chemical Oxygen Demand AccuracyLow Range
Chemical Oxygen Demand MethodAdaptation of the USEPA 410.4
ISO dichromate methods
Mercury-free dichromate green method (LR & MR); dichromate method (HR)
Chloride Range0.0 to 20.0 mg/L (as Cl⁻)
Chloride Resolution0.1 mg/L
Chloride Accuracy±0.5 mg/L ±6% of reading at 25 °C
Chlorine Dioxide Range0.00 to 2.00 mg/L (as ClO2)
Chlorine Dioxide Resolution0.01 mg/L
Chlorine Dioxide Accuracy±0.10 mg/L ±5% of reading
Chlorine Dioxide MethodAdaptation of the Chlorophenol Red method.
Free Chlorine Range0.00 to 5.00 mg/L (as Cl2)
Ultra Low Range
Free Chlorine Resolution0.01 mg/L
Ultra Low Range
Free Chlorine Accuracy±0.03 mg/L ±3% of reading
Ultra Low Range
Total Chlorine Range0.00 to 5.00 mg/L (as Cl2)
Ultra Low Range
Total Chlorine Resolution0.01 mg/L
Ultra Low Range
Total Chlorine Accuracy±0.03 mg/L ±3% of reading
Ultra Low Range
Chlorine MethodAdaptation of the EPA 330.5 DPD method
Free Chlorine (ULR) & Total Chlorine (UHR)
Chromium, Hexavalent RangeLow Range
Chromium, Hexavalent Resolution1 μg/L
Chromium, Hexavalent AccuracyLow Range
Chromium, Hexavalent MethodAdaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method.
Color, Water Range0 to 500 PCU (Platinum Cobalt Units)
Color, Water Resolution1 PCU
Color, Water Accuracy±10 PCU ±5% of reading
Color, Water MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method.
Copper RangeLow Range
Copper Resolution0.001 mg/L; 0.01 mg/L
Copper AccuracyLow Range
Copper MethodAdaptation of the EPA bicinchoninate method
Cyanuric Acid Range0 to 80 mg/L (as CYA)
Cyanuric Acid Resolution1 mg/L
Cyanuric Acid Accuracy±1 mg/L ±15% of reading
Cyanuric Acid MethodAdaptation of the turbidimetric method
Fluoride RangeLow Range
Fluoride Resolution0.01 mg/L; 0.1 mg/L
Fluoride AccuracyLow Range
Fluoride MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method
Hardness, Total RangeLow Range
Hardness, Total Resolution1 mg/L
Hardness, Total AccuracyLow Range
Hardness, Total MethodAdaptation of the EPA recommended method 130.1
Hardness, Calcium Range0.00 to 2.70 mg/L (as CaCO3)
Hardness, Calcium Resolution0.01 mg/L
Hardness, Calcium Accuracy±0.11 mg/L ±5% of reading
Hardness, Calcium MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method
Hardness, Magnesium Range0.00 to 2.00 mg/L (as CaCO3)
Hardness, Magnesium Resolution0.01 mg/L
Hardness, Magnesium Accuracy±0.11 mg/L ±5% of reading
Hardness, Magnesium MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method
Hydrazine Range0 to 400 μg/L (as N2H4)
Hydrazine Resolution1 μg/L
Hydrazine Accuracy±4% of full scale reading
Hydrazine MethodAdaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88, p-Dimethylaminobenzaldehyde method
Iodine Range0.0 to 12.5 mg/L (as I2)
Iodine Resolution0.1 mg/L
Iodine Accuracy±0.1 mg/L ±5% of reading
Iodine MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method
Iron RangeLow Range
Iron Resolution0.001 mg/L; 0.01 mg/L
Iron AccuracyLow Range
Iron MethodLow Range
Magnesium Range0 to 150 mg/L (as Mg2+)
Magnesium Resolution1 mg/L
Magnesium Accuracy±5 mg/L ±3% of reading
Magnesium MethodAdaptation of the Calmagite method
Manganese RangeLow Range
Manganese Resolution1 μg/L; 0.1 mg/L
Manganese AccuracyLow Range
Manganese MethodLow Range
Molybdenum Range0.0 to 40.0 mg/L (as Mo6+)
Molybdenum Resolution0.1 mg/L
Molybdenum Accuracy±0.3 mg/L ±5% of reading
Molybdenum MethodAdaptation of the mercaptoacetic acid method
Nickel RangeLow Range
Nickel Resolution0.001 mg/L; 0.01 g/L
Nickel AccuracyLow range
Nickel MethodLow Range
Nitrate Range0.0 to 30.0 mg/L (as NO3– N)
16 mm vial
Nitrate Resolution0.1 mg/L
Nitrate Accuracy±0.5 mg/L ±10% of reading
16 mm vial
Nitrate MethodAdaptation of the cadmium reduction method
16 mm vial
Nitrite RangeFreshwater
Low Range
Nitrite ResolutionFreshwater
Nitrite AccuracyFreshwater
Low Range
Nitrite MethodLow Range and Seawater
Nitrogen, Total RangeLow Range
Nitrogen, Total Resolution0.1 mg/L; 1 mg/L
Nitrogen, Total AccuracyLow Range
Nitrogen, Total MethodChromotropic acid method
Oxygen, Scavenger Range0 to 1000 μg/L (as DEHA)
0.00 to 1.50 mg/L (as Carbohydrazide)
0.00 to 2.50 mg/L (as Hydroquinone)
0.00 to 4.50 mg/L (as ISO-ascorbic acid)
Oxygen, Scavenger Resolution1 μg/L (DEHA); 0.01 mg/L
Oxygen, Scavenger Accuracy±5 μg/L ±5% of reading
Oxygen, Scavenger MethodAdaptation of the iron reduction method
Ozone Range0.00 to 2.00 mg/L (as O3)
Ozone Resolution0.01 mg/L
Ozone Accuracy±0.02 mg/L ±3% of reading
Ozone MethodColorimetric DPD Method
Phosphate RangeFreshwater
Low Range
Phosphate ResolutionFreshwater
Phosphate AccuracyFreshwater
Low Range
Phosphate MethodFreshwater Low Range
Phosphorous, Acid Hydrolyzable Range0.00 to 1.60 mg/L (as P)
Phosphorous, Acid Hydrolyzable Resolution0.01 mg/L
Phosphorous, Acid Hydrolyzable Accuracy±0.05 mg/L or ±5% of reading
Phosphorous, Acid Hydrolyzable MethodAdaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method
Phosphorous, Reactive RangeLow Range
Phosphorous, Reactive Resolution0.01 mg/L; 0.1 mg/L
Phosphorous, Reactive AccuracyLow Range
Phosphorous, Reactive MethodLow Range
Phosphorous, Total RangeLow Range
Phosphorous, Total AccuracyLow Range
Phosphorous, Total ResolutionLow Range
Phosphorous, Total MethodLow Range
Potassium Range0.0 to 20.0 mg/L (as K)
Potassium Resolution0.1 mg/L
Potassium Accuracy±3.0 mg/L ±7% of reading
Potassium MethodAdaptation of the Turbidimetric Tetraphenylborate method
Silica RangeLow Range
Silica Resolution0.01 mg/L; 1 mg/L
Silica AccuracyLow Range
Silica MethodLow Range
Silver Range0.000 to 1.000 mg/L (as Ag)
Silver Resolution0.001 mg/L
Silver Accuracy±0.020 mg/L ±5% of reading
Silver MethodAdaptation of the PAN method
Sulfate Range0 to 150 mg/L (as SO42-)
Sulfate Resolution1 mg/L
Sulfate Accuracy±5 mg/L ±3% of reading
Sulfate MethodTurbidimetric – Sulfate is precipitated with barium chloride crystals
Zinc Range0.00 to 3.00 mg/L (as Zn)
Zinc Resolution0.01 mg/L
Zinc Accuracy±0.03 mg/L ±3% of reading
Zinc MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method
Input Channels1 pH electrode input and 5 photometer wavelengths
pH Electrodedigital pH electrode (not included)
Photometer/Colorimeter Light Source5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters
Photometer/Colorimeter Light Detectorsilicon photodetector
Bandpass Filter Bandwidth8 nm
Bandpass Filter Wavelength Accuracy±1 nm
Cuvette Typeround, 24.6 mm
Number of Methods128 max.
GLPcalibration data for connected pH electrode
Display128 x 64 pixel LCD with backlight
Logging Typelog on demand with user name and sample ID optional input
Logging Memory1000 readings
ConnectivityUSB-A host for flash drive; micro-USB-B for power and computer connectivity
Power Supply5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
Battery Type/Life3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement
Environment0 to 50.0 oC (32 to 122.0 oF); 0 to 95% RH, non-condensing
Weight1.0 kg (2.2 lbs.)
Dimensions206 x 177 x 97 mm (8.1 x 7.0 x 3.8″)
Ordering InformationHI83399 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.

 


Hanna HI-83399-02 – Manual


Produk asli Kami distributor langsung Hanna . Harga murah dan berkualitas bergaransi tentunya. dapat di kirim ke seluruh wilayah indonesia.

Dalam pengiriman produk yang pelanggan beli, sebelumnya sudah kami cek untuk memastikan produk dalam keadaan baik dan siap kirim.


 

Additional Information

Brand

Hanna

Model

HI-83399-02

Made In

Romania

Weight

2,5 kg

Product Enquiry

TESTIMONI PELANGGAN

alhamdulillah pesanan sudah sampai di Bengkulu.Pengalaman order di karyamandiritechindo.com Respon cepat. Pengiriman Cepat dan Free, Aman & Terpercaya.

Ibu Natalia Dan Ria
PT. AGricinal

Terimakasih karyamandiritechindo.com, orderannya sudah sampai dengan selamat Kurir Syariftama Express sangat ramah

PT. Bumi Bangun Perkasa
Ibu Rizeki

Order yg kedua, seperti biasa produk sangat memuaskan dan pelayannya ramah, Terimakasih Pak Aji Amanda Semoga di orderan berikutnya tetap TOP

PT. Daruna

Puas banget belanja di karyamandiritechindo.com. pengiriman cepat kualitas produk mantap.

PT. Niaga Andalan Serayat

BUAT PERMINTAAN HARGA