Hanna HI-9147 Portable Galvanic Dissolved Oxygen Meter
Karya Mandiri Techindo has a wide range of Hanna products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..
The HI9147 is a rugged, water-resistant dissolved oxygen (DO) meter designed for aquaculture applications. The meter and probe use galvanic sensor technology where the electrodes’ potential difference drives the reaction, requiring no external voltage. Oxygen diffuses across the membrane and the system establishes a current proportional to the concentration of dissolved oxygen present. HI9147 comes with a galvanic, HDPE membrane caps, electrolyte fill solution, a protective shield, and sturdy carrying case.
- Easily Replaceable Membrane Caps
- Manual Calibration
- Galvanic Measuring System
- DIN Connector
Features Hanna HI-9147 Portable Galvanic Dissolved Oxygen Meter
- Galvanic Measuring System, requiring no external voltage
- Silver cathode and zinc anode in an electrolyte solution with a polymer membrane
- Automatic calibration at one or two points to 100% and/or 0% saturation
- Automatic Temperature Compensation (ATC) using a high-accuracy, built-in, linearized, thermistor temperature sensor
- Altitude compensation up to 4000 meters with a 100-meter resolution
- Salinity compensation is adjustable from 0 to 51 g/L (ppt) with a 1 g/L resolution for the measurement of DO in brackish and sea water
- Auto end point mode freezes a reading on the display once a stable measurement is obtained
- Good Laboratory Practice allows users to recall calibration information
- Replaceable, pretensioned, polytetrafluoroethylene (PTFE) membranes with a screw cap design
Specifications Hanna HI-9147 Portable Galvanic Dissolved Oxygen Meter
SKU | HI9147-web |
---|---|
Product Name | Portable Galvanic Dissolved Oxygen Meter – HI9147 |
Quote Required | Yes |
Dissolved Oxygen Range | 0.00 to 50.00 ppm (mg/L); 0.0 to 600.0% saturation |
Dissolved Oxygen Resolution | 0.1 mg/L (ppm); 1% saturation |
Dissolved Oxygen Accuracy | ±1% of reading |
Dissolved Oxygen Calibration | manual, in saturated air |
Dissolved Oxygen Temperature Compensation | automatic from 0 to 50°C (32 to 122°F) |
Salinity Compensation | 0 to 51 g/L (ppt) (1 g/L resolution) |
Altitude Compensation | 0 to 4000 m (resolution 100 m) |
Temperature Range | 0.0 to 50.0°C / 32.0 to 122.0°F |
Temperature Resolution | 0.1°C; 1°F |
Temperature Accuracy | ±0.2°C; ±1°F (excluding probe error) |
DO Probe | galvanic DO probe, internal temperature sensor, DIN connector |
Battery Type/Life | 1.5V AAA (3) / approximately 1000 hours of continuous use without backlight |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Dimensions | 185 x 72 x 36 mm (7.3 x 2.8 x 1.4”) |
Weight | 450 g (15.9 oz.) |
Ordering Information | HI9147 is supplied complete with HI76409 probe, HI76409A/P pre-formed HDPE DO membranes (2), HI7042S electrolyte solution (30 mL), batteries, instructions and rugged carrying case |