Product Description
Hanna HI-96822 Digital Refractometer for Seawater Analysis
Karya Mandiri Techindo has a wide range of Hanna Instruments products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..
The HI96822 Digital Refractometer eliminates the uncertainty associated with mechanical refractometers by measuring the refractive index to determine the salinity of natural and artificial seawater including brackish, ocean water or saltwater aquarium. The instrument converts the refractive index of a sample to PSU, ppt and specific gravity. These conversions are based on respected scientific publications using the physical properties of seawater (not sodium chloride). The HI96822 is an easy to use tool for measuring salinity in natural and artificial seawater whether in the field, lab or at home.
- Designed for seawater salinity analysis (not NaCl)
- Automatic Temperature Compensation
- High accuracy measurements displayed as PSU, ppt and specific gravity
Making a Standard Solution
Sodium Chloride solutions can be used to check the accuracy of the meter. The table below lists two Sodium Chloride solutions and their expected ppt Seawater value.
To make a Standard NaCl Solution (g/100 g), follow the procedure below
- Place container (such as a glass vial or dropper bottle that has a cover) on an analytical balance.
- Tare the balance.
- To make an X NaCl solution weigh out X grams of high purity dried Sodium Chloride (CAS #: 7647-14-5: MW 58.44) directly into the container.
- Add distilled or deionized water to the beaker so the total weight of the solution is 100g.
Example Standard NaCl solution
NaCl (g) | Water (g) | Total | Expected Seawater value (ppt) | |
3.5% NaCl | 3.50 | 96.50 | 100.000 | 34 |
10% NaCl | 10.00 | 90.00 | 100.000 | 96 |
Refractive Index
The HI96822 takes measurements based on a sample’s refractive index. Refractive index is a measurement of how light behaves as it passes through the sample. Depending on the sample’s composition, light will refract and reflect differently. By measuring this activity with a linear image sensor, the sample’s refractive index can be assessed and used to determine its physical properties such as concentration and density. In addition to the linear image sensor, the HI96822 uses an LED light, prism and lens to make measurement possible.
Variations in temperature will affect the accuracy of refractometry readings, so the use of temperature compensation is highly recommended for reliable results. The HI96822 contains a built-in temperature sensor and is programmed specialized algorithms then apply temperature compensation to the measurement and convert the refractive index to: PSU (Practical Salinity Units), ppt (part per thousand) or S.G. (Specific Gravity) (20/20). PSU is defined as the conductivity ratio of seawater to a standard KCl solution. It is based upon the work of the UNESCO, ICES, SCOR, and IAPSO. This information is published in The Joint Panel of Oceanographic Tables and Standards. An older salinity scale is ppt (10-3), where salinity is defined by “the salt content is the weight of the inorganic salts contained in 1 kg of seawater if all bromide and iodide are replaced by an equivalent amount of oxides” (Knudsen, 1901). Specific Gravity (20/20) is based upon the published relationship between density at 20 °C and the mass of dissolved salts in the seawater sample (CRC Handbook of Chemistry and Physics, 87th Edition).
Features at-a-glance
One-point calibration
- Calibrate with distilled or deionized water
Small sample size
- Sample size can be as small as 2 metric drops (100 μl)
Automatic Temperature Compensation (ATC)
- Samples automatically compensated for temperature variations
Quick, accurate results
- Readings are displayed in approximately 1.5 seconds
Dual-level LCD
- The dual-level LCD displays measurement and temperature readings simultaneously
Stainless steel sample well
- Easy to clean and corrosion-resistant
Battery indicators
- Battery percent level remaining at startup and low battery indicator
Automatic shut-off
- To conserve battery life the meter shuts off automatically after three minutes of non-use
IP65 water resistant protection
- Water resistant ABS plastic casing designed to perform under laboratory and field conditions.
Specifications Hanna HI-96822 Digital Refractometer for Seawater Analysis
SKU | HI96822 |
---|---|
Product Name | Digital Refractometer for Seawater Analysis – HI96822 |
Quote Required | Yes |
Salinity (PSU) Range | 0 to 50 PSU |
Salinity (PSU) Resolution | 1 PSU |
Salinity (PSU) Accuracy | ±2 PSU |
Salinity Range | 0 to 150 ppt |
Salinity Resolution (ppt) | 1 ppt |
Salinity Accuracy (ppt) | ±2 ppt |
Specific Gravity Range | 1.000 to 1.114 Specific Gravity (20/20) |
Specific Gravity Resolution | 0.001 Specific Gravity (20/20) |
Specific Gravity Accuracy | ±0.002 Specific Gravity (20/20) |
Temperature Range | 0 to 80°C (32 to 176°F) |
Temperature Resolution | 0.1°C (0.1°F) |
Temperature Accuracy | ±0.3 °C (±0.5 °F) |
Temperature Compensation | automatic between 0 and 40°C (32 to 104°F) |
Automatic Shut-Off | after three minutes of inactivity |
Battery Type/Life | 9V / approximately 5000 readings |
Dimensions | 192 x 102 x 67 mm (7.6 x 4.01 x 2.6”) |
Weight | 420 g (14.8 oz.) |
Refractometer Light Source | yellow LED |
Minimum Sample Volume | 100 μL (to cover prism totally) |
Sample Cell | stainless steel ring and flint glass prism |
Measurement Time | approximately 1.5 seconds |
Ordering Information | HI96822 is supplied with battery and instruction manual |
Notes | Enclosure Rating |