Product Description
Hanna HI-98197 Ultra Pure Water EC/Resistivity Waterproof Portable Meter
Karya Mandiri Techindo has a wide range of Hanna Instruments products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..
Features Hanna HI-98197 Ultra Pure Water EC/Resistivity Waterproof Portable Meter
- Conductivity and resistivity – high resolution of 0.001µS/cm for conductivity and 0.1 MΩ•cm for resistivity
- Calibration – Perform up to a five point calibration for enhanced accuracy
- Temperature Compensation – Automatic Temperature Compensation & configurable temperature coefficient range from 0.00 to 10.00%/°C
- Approximately 100 hour battery life – powered by (4) 1.5V AA Batteries
- Four-ring platinum probe – this probe can cover low EC samples to 1000 mS/cm (actual EC) – HI-763123
- Waterproof – IP67 rated waterproof, rugged enclosure
- Clear display – Graphic LCD display with multi-function virtual keys
- Autohold – automatically holds the first stable reading on the display
Designed for water professionals
High purity water used in power generation, semi-conductor manufacturing, and other industries can be difficult to measure due to the ability of carbon dioxide (CO2) to diffuse into water and form carbonic acid (H2CO3).
Carbonic acid quickly dissociates into hydrogen ions (H+) and bicarbonate ions (HCO–3). These ions will increase the conductivity and decrease the resistivity of the water. In order to measure high purity water accurately, it is necessary to perform a continuous flow measurement.
HI-98197 uses the HI-763123 four-ring probe with a threaded connection that is screwed into a stainless steel body flow cell. The flow cell is then connected to a water source to more accurately determine the conductivity or resistivity without exposure to air. Hi-98197 is an ideal meter for monitoring the efficiency of a mixed bed resin or equivalent system that produces high purity water of 18.2 MΩ•cm at 25°C.
(Photograph shows the HI-605453 flow cell for ultrapure water)
Backlit Graphic LCD Display
The HI-98197 features a backlit graphic LCD with on-screen help. The graphic display allows for the use of virtual keys to provide for an intuitive user interface.
Quick connect probe
The HI-763123 four-ring platinum conductivity probe with a threaded connection features a quick connect DIN connector to make attaching and removing the probe simple and easy.
Waterproof protection
The meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1m for up to 30 minutes.
Calibration
Choose from seven memorised standards and obtain up to a five point conductivity calibration. For salinity (% range), HI-7037 standard allows users to perform a one point calibration.
Measurement
EC and TDS measurements are fully customisable and include: cell constant selection between 0.010 and 10.000, selection of linear or natural water (non-linear) or no temperature compensation (for actual conductivity reading), configurable temperature compensation coefficient range from 0.00 to 10.00%/°C, choice of reference temperatures of 15°C, 20°C and 25°C, and a selectable TDS factor between 0.40 and 1.00.
Ten sets of customised measurement parameters can be stored as a user profile and later recalled.
Autohold
Pressing Autohold during measurement will automatically hold the first stable reading on the display.
USP <645>
HI-98197 can be used to perform all three stages of USP <645> method required for EC measurement of water for injection and generates a report when any of the three stages are met. An on-screen guide instructs on each USP stage. A progress bar displays reading stability progress towards meeting stage 2 requirements.
Data logging
The HI-98197s allow storage of up to 400 log-on demand samples or 1000 lot logging samples that can be later transferred to a PC with the supplied HI-920015 USB cable and HI-92000 software.
GLP
Comprehensive GLP functions are directly accessible by pressing the GLP Key. Calibration data, including date, time and calibration values are stored for retrieval at a later time.
Intuitive keypad
The fitted rubber keypad has dedicated keys for power, backlight, up/down arrows, help and alphanumeric characters. The meter also features two virtual soft keys that navigate the user through the configuration of each parameter, meter setup, and logging of data. The interface is intuitive for any user’s level of experience.
Dedicated help key
Contextual help is always available through a dedicated HELP key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting/option being viewed.
Setup screen
Our extensive setup screen features a host of configurable options such as time, date, temperature units and language for help screens and guides.
PC Connectivity
Logged data can be transferred to a Windows compatible PC with the included HI-920015 micro USB cable and HI-92000 software.
Long Battery Life
The display of the meter has a battery icon indicator to show the remaining power. The meter uses four 1.5V AA batteries that provide up to 200 hours of battery life.
Specifications Hanna HI-98197 Ultra Pure Water EC/Resistivity Waterproof Portable Meter
SKU | HI98197 |
---|---|
Product Name | Ultra Pure Water EC/Resistivity Waterproof Portable Meter – HI98197 |
Quote Required | Yes |
EC Range | 0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual conductivity; temperature compensated to 400 mS/cm) |
EC Resolution | 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm |
EC Accuracy | ±1% of reading (±0.01 μS/cm or 1 digit, whichever is greater) |
EC Calibration | automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) |
TDS Range | 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L) |
TDS Resolution | 0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L) |
TDS Accuracy | ±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater) |
TDS Calibration | based on conductivity calibration |
EC/TDS Temperature Compensation | noTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear – ISO/DIN 7888 (-0 to 36 °C; 32 to 96.8°F) |
Temperature Correction Coefficient | 0.00 to 10.00 %/°C |
EC to TDS Conversion Factor | 0.40 to 1.00 |
Reference Temperature | 15°C, 20°C and 25°C |
EC/TDS Multi-range Measurement Modes | autorange, autoend, lock and fixed range |
Salinity (% NaCl) Range | 0.0 to 400.0 % |
Salinity (% NaCl) Resolution | 0.1 % |
Salinity (% NaCl) Accuracy | ±1% of reading |
Salinity (% NaCl) Calibration | Max. one point only in % range (with HI7037 standard) |
Salinity (PSU) Range | 0.00 to 42.00 (PSU) |
Salinity (PSU) Resolution | 0.01 PSU |
Salinity (PSU) Accuracy | ±1% of reading |
Salinity (PSU) Calibration | based on conductivity calibration |
Salinity Range | 0.00 to 80.00 (ppt) |
Salinity Resolution (ppt) | 0.01 ppt |
Salinity Accuracy (ppt) | ±1% of reading |
Salinity Calibration (ppt) | based on conductivity calibration |
Resistivity Range | 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•c |
Resistivity Resolution | 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm |
Resistivity Accuracy | ±1% of reading (±10 Ω or 1 digit, whichever is greater) |
EC/TDS Probe | HI763123 platinum, four ring conductivity/TDS probe with internal temperature sensor and 1 m cable (included) |
Logging Type | Log-on-demand |
Logging Memory | up to 10 |
Connectivity | opto-isolated USB with optional HI 92000 software and micro USB cable |
Automatic Shut-Off | user selectable |
Battery Type/Life | 1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight |
Environment | 0 to 50°C (32 to 122°F); RH 100% (IP67) |
Dimensions | 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) |
Weight | 400 g (14.2 oz.) |
Ordering Information | HI98197 is supplied with HI763123 conductivity probe, HI605453 stainless steel flow cell, HI7033M 84 μS/cm calibration solution (230 mL), HI7031M 1413 μS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instructions and rugged carrying case. |
Hanna HI-98197 – Manual
KARYA MANDIRI TECHINDO adalah Supplier Hanna HI-98197 Waterproof Portable Meter dan juga menjual Brand Hanna Instruments. Lihat produk kami lainnya di sini JSI, SGI, SMG atau hubungi kami lewat Whatsapp 0821-3010-0456 atau via email [email protected].