Hanna HI-9835 EC/TDS/NaCl/°C Portable Meter

Hanna HI-9835 EC/TDS/NaCl/°C Portable Meter

The HI9835 is an ideal solution to accurately measure conductivity (EC), total dissolved solids (TDS), salinity (NaCl), and temperature within one handheld meter. With the autoranging feature of the EC and TDS ranges, the meter automatically sets the meter to the scale with the highest possible resolution. Among the many user-selectable features include automatic (ATC), manual (MTC) or disabled temperature compensation, an adjustable temperature coefficient (β), and TDS conversion factor.

Product Description

Hanna HI-9835 EC/TDS/NaCl/°C Portable Meter

Karya Mandiri Techindo has a wide range of Hanna Instruments products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..

The HI9835 is an ideal solution to accurately measure conductivity (EC), total dissolved solids (TDS), salinity (NaCl), and temperature within one handheld meter. With the autoranging feature of the EC and TDS ranges, the meter automatically sets the meter to the scale with the highest possible resolution. Among the many user-selectable features include automatic (ATC), manual (MTC) or disabled temperature compensation, an adjustable temperature coefficient (β), and TDS conversion factor. If pressed during measurement, the auto endpoint button freezes the reading display when stability is reached for more convenient data recording.

With an IP67 rating, the housing of the HI9835 is completely waterproof and built to withstand harsh field conditions. The HI76309 EC/TDS probe that comes with the meter is a four-ring probe with an internal temperature sensor that resists clogging and is easy to clean. The large, multi-level LCD displays the primary reading, temperature, calibration guides, and meter functions simultaneously. Symbols and messages on the LCD indicate meter status and help to guide users through operations.

Features at-a-glance

Four-ring Probe

  • The HI76309 is a stainless steel four-ring probe that offers an accurate solution for EC, TDS, and salinity readings. Four-ring technology allows for a larger range of measurement within a single probe, whereas two probe technology is somewhat limited in the range in which it can measure. The probe features a built-in temperature probe to allow for temperature compensated readings, as well as a protective PVC sleeve that assures durability when taking measurements outdoors.

Three Measurement Modes

  • HI9835 offers three measurement modes: EC, TDS, and salinity. Users can easily switch between measurement modes with a simple press of the ‘Range’ button. EC measurements range from 0.00 to 500.0 mS/cm (actual EC); TDS measurements range from 0.00 to 400.0 ppt (actual TDS); salinity measurements range from 0.0 to 400.0% NaCl.

Adjustable TDS Factor

  • The TDS value in aqueous solutions is directly proportional to conductivity. The ratio between the two parameters depends on the solution being measured. The HI9835 has an adjustable TDS factor from 0.40 to 0.80, allowing users to choose the conversion factor that is the most appropriate for their particular solution.

Automatic Temperature Compensation

  • Since temperature has such a dramatic effect on conductivity (and thus TDS and salinity readings), having a meter that offers temperature compensated readings is invaluable. The probe of the HI9835 features a built-in temperature sensor that automatically accounts for the effects of temperature in the range of -20.0 to 120.0°C (-4.0 to 248.0°F). Users also have the option to select manual temperature compensation or disable it for actual EC and TDS measurements.

Adjustable Temperature Compensation Coefficient

  • The temperature compensation coefficient, also known as β, is adjustable from 0.00 to 6.00%/°C; this factor corrects the reading a set percentage % for each degree Celsius change in the sample.

Automatic Calibration

  • The HI9835 can be automatically calibrated at one point in a standard EC solution. A range of memorized standards can be used for EC calibration which will automatically calibrate TDS readings. Salinity can be calibrated to one point using the HI7037 100.0% NaCl standard solution.

Instability Indicator

  • The HI9835 displays a clock tag that will disappear when a reading has achieved stability.

Battery Error Prevention System (BEPS)

  • The Battery Error Prevention System detects when the batteries become too weak to ensure reliable measurements.

Specifications Hanna HI-9835 EC/TDS/NaCl/°C Portable Meter

 
SKU HI9835
Product Name EC/TDS/NaCl/°C Portable Meter – HI9835
Quote Required Yes
EC Range 0.00 to 29.99 μS/cm; 30.0 to 299.9 μS/cm; 300 to 2999 μS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm (actual EC)*
EC Resolution 0.01 μS/cm; 0.1 μS/cm; 1 μS/cm; 0.01 mS/cm; 0.1 mS/cm
EC Accuracy ±1% of reading (±0.05 μS/cm or 1 digit)
EC Calibration automatic, one point with six memorized values (84, 1413, 5000, 12880, 80000, 111800 μS/cm)
TDS Range 0.00 to 14.99 mg/L (ppm); 15.0 to 149.9 mg/L (ppm); 150 to 1499 mg/L (ppm); 1.50 to 14.99 g/L (ppt); 15.0 to 100.0 g/L
TDS Resolution 0.01 mg/L (ppm); 0.1 mg/L (ppm); 1 mg/L (ppm); 0.01 g/L (ppt); 0.1 g/L (ppt)
TDS Accuracy ±1% of reading (±0.03 mg/L (ppm) or 1 digit, whichever greater)
EC/TDS Temperature Compensation automatic or manual from –20.0 to 120.0 °C (-4.0 to 248.0°F) (can be disabled for measuring conductivity activity)
Temperature Correction Coefficient selectable from 0.00 to 6.00%/°C (EC and TDS only); default value is 1.90%/°C
EC to TDS Conversion Factor selectable from 0.40 to 0.80 (default value is 0.50)
Reference Temperature 20°C or 25°C
Salinity (% NaCl) Range 0.0 to 400.0% NaCl
Salinity (% NaCl) Resolution 0.1%
Salinity (% NaCl) Accuracy ±1% of reading
Salinity (% NaCl) Calibration one point with HI7037 calibration solution
Temperature Range -20.0 to 120.0°C (-4.0 to 248.0°F)
Temperature Resolution 0.1°C
Temperature Accuracy ±0.2% FS (excluding probe error)
EC/TDS Probe HI76309 EC/TDS probe four-ring conductivity probe with internal temperature sensor, DIN connector with 1m cable
Automatic Shut-Off after 5, 10, 20 and 60 minutes (can be disabled)
Battery Type/Life 1.5V AAA batteries (3) /approximately 200 hours of continuous use without backlight (50 hours with backlight on
Environment 0 to 50°C (32 to 122°F); RH max 95%
Dimensions 185 x 72 x 36 mm (7.3 x 2.8 x 1.4”)
Weight 300 g (10.6 oz)
Ordering Information HI9835 is supplied with HI76309 conductivity probe, batteries, instructions, and rugged carrying case.

 

 

 

Hanna HI-9835 – Manual

KARYA MANDIRI TECHINDO adalah Supplier Hanna HI-9835 EC/TDS/NaCl/°C Portable Meter dan juga menjual Brand Hanna Instruments. Lihat produk kami lainnya di sini JSISGISMG atau hubungi kami lewat Whatsapp 0821-3010-0456 atau via email [email protected].


 

Additional Information

Brand

Hanna

Model

HI-9835

Made In

Romania

Weight

1,5 kg

Product Enquiry

TESTIMONI PELANGGAN

alhamdulillah pesanan sudah sampai di Bengkulu. Pengalaman order di karyamandiritechindo.com Respon cepat. Pengiriman Cepat dan Free, Aman & Terpercaya.

Ibu Natalia Dan Ria
PT. AGricinal

Terimakasih karyamandiritechindo.com, orderannya sudah sampai dengan selamat Kurir Syariftama Express sangat ramah

PT. Bumi Bangun Perkasa
Ibu Rizeki

Order yg kedua, seperti biasa produk sangat memuaskan dan pelayannya ramah, Terimakasih Pak Aji Amanda Semoga di orderan berikutnya tetap TOP

PT. Daruna

Puas banget belanja di karyamandiritechindo.com. pengiriman cepat kualitas produk mantap.

PT. Niaga Andalan Serayat

BUAT PERMINTAAN HARGA