Product Description
Hanna HI96701 Free Chlorine Portable Photometer
Karya Mandiri Techindo has a wide range of Hanna Instruments products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..
ergonomic, portable design. Using the HI93701-0 ready made reagent a user can accurately determine the concentration of free chlorine in water samples within a 0.00 to 5.00 mg/L (ppm) range. The HI96701 offers many advanced features including the exclusive CAL-Check™ function used for performance verification and calibration of the meter.
- CAL Check™ Validation and Calibration
- Built-in Timer
- Automatic shut off
The HI96701 portable photometer is for the measurement of free chlorine in a wide variety of water samples. Hanna’s portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check™ feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.
Features at-a-glance
- Allows for performance verification and calibration of the meter using a CAL Check NIST traceable secondary standard.
GLP
- Records the date of the last user calibration performed.
Built in timer
- Ensures the appropriate reaction time is used for the chemical reaction. At the end of the timer the meter will automatically take the reading. This feature ensures consistency across multiple users.
Indexing indent on meter
- The meter has an indent that allows for a lock and key fit with the cuvette cap. This ensures that the cuvette is indexed consistently (same position) in order to maintain the same path length for accurate results.
Cooling Lamp Indicator
- It is necessary to maintain a consistent temperature of the optical components in order to maintain a narrow wavelength band of light. This photometer has a cooling lamp indicator that is displayed for a short period of time before each measurement in order to allow the components to cool and obtain the highest accuracy possible.
Error messages
- Messages on display alerting to problems including no cap, over range and under range readings, and light source error.
Auto-shut off
- Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally not turned off.
Battery status indicator – The instrument has a battery level indicator to display remaining life as follows:
- 3 lines for 100 % capacity
- 2 lines for 66 % capacity
- 1 line for 33 % capacity
- Battery icon blinks when the capacity is less than 10 %.
Units of measure – Appropriate unit of measure is displayed along with reading.
Free chlorine is one of the oldest and most common forms of disinfection, chlorine improves water quality by destroying disease-producing microorganisms, and by reacting with other organic and inorganic substances. Chlorine levels must be actively monitored to ensure sufficient chlorine is present for disinfection, as well as to control adverse effects, such as taste, odor and potential reactions with organic matter to form harmful disinfection byproducts.
The HI96701 uses an adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G to measure free chlorine concentrations of less than 5.00 mg/L (ppm). When the DPD reagent is added to samples containing free chlorine, the sample will turn a pink hue; the greater the concentration, the deeper the color. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complimentary color, and the emitted radiation is dependent upon concentration. For free chlorine determination, a narrow band interference filter at 525 nm (green) allows only green light to be detected by the silicon photodetector and omits all other visible light emitted from the tungsten lamp. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.
The HI96701 is available as a kit (HI96701C) which includes
- Portable Photometer
- Sample cuvettes (2)
- Caps
- CAL Check™ standards with certificate
- Cuvette cleaning cloth
- Scissors
- Rugged carrying case
- Carrying case has thermoformed insert for meter and accessories
*Reagents ordered separately
CAL Check™ standards with certificate
The HI96701-11 CAL Check™standards are used for calibration and performance verification of photometers with the CAL Check function.
Supplied with Certificate of Analysis
- Lot number
- Expiration date
- Standard value @ 25 °C
- Reference meter NIST traceable
Provided storage containers
- Light tight
- Protects from accidental breakage
Specifications Hanna HI96701 Free Chlorine Portable Photometer
Specification Name | Detail |
---|---|
SKU | HI96701 |
Chlorine, Free Range | 0.00 to 5.00 mg/L (ppm) |
Chlorine, Free Resolution | 0.01 mg/L (ppm) from 0.00 to 3.50 mg/L; 0.10 mg/L above 3.50 mg/L |
Chlorine, Free Accuracy | ±0.03 mg/L ±3% of reading |
Chlorine, Free Method | adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G |
Light Source | tungsten lamp |
Light Detector | silicon photocell with narrow band interference filter @ 525 nm |
Power Supply | 9V battery |
Auto-off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Dimensions | 192 x 104 x 69 mm (7.6 x 4.1 x 2.7”) |
Weight | 320g (11.3 oz.) |
Hanna HI96701 – Manual
KARYA MANDIRI TECHINDO adalah Supplier Hanna HI96701 Free Chlorine Portable Photometer dan juga menjual Brand Hanna Instruments. Lihat produk kami lainnya di sini JSI, SGI, SMG atau hubungi kami lewat Whatsapp 0821-3010-0456 atau via email [email protected].