Product Description
Lutron DM-9983G Green Power Smart Multimeter
Karya Mandiri Techindo has a wide range of Lutron products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..
Battery-free multimeter Just spin to store energy to use. Or you can put the battery to use.
Measurement functions ACV, ACA, DCV, DCA, Ohms, Continuity beeper, Hz, Capacitance, Diode.
Features Lutron DM-9983G Green Power Smart Multimeter
- Green power, battery is no need, power supply from the handy generator, operate the generator 10 to 20 seconds will offer 10 minutes energy typically
- Hybrid power, meter also can supply by the battery
- Meet CAT III-600 V
- 6000 counts A/D, high resolution
- ACV, ACA, DCV, DCA, ohms, continuity, Hz Capacitance, Diode, Data hold
- Smart function, Auto range or manual range with hold
- Smart operation, Build in 4 intelligent function : ” V “, ” Ω “, ” mA “. ” 10A “
- ” V ” function can select ACV, DCV automatically with auto range
- ” Ω ” function can select the Resistance , Diode, Continuity beeper, Capacitance automatically withauto range
- ” 10A ” ” mA ” function can measure ACA, DCA with auto range
- Data hold ( auto range )
- Auto shut off is available to save battery life
- Both 10 A, mA current range are build fuses for safety consideration
- 10 M ohm impedance for voltage circuit
- Built-in overload protection for most ranges
- LSI circuit provides high reliability and durability
- Patent
- Uses durable, long-lasting components, enclosed in strong, light weight ABS-plastic housing
- Full line optional adapters : Clamp adapter Tachometer adapter, Pressure adapter, Humidity Adapter, Sound level adapter, Anemometer adapter, Light adapter, EMF adapter
Specifications Lutron DM-9983G Green Power Smart Multimeter
Green power and Hybrid power | * Green power, battery is no need, power supply from the handy generator, operate 10 to 20 seconds the generator will offer 10 minutes energy typically. * Hybrid power, meter also can supply by the battery power. |
---|---|
Display | 46 mm x 45 mm large LCD display |
Measurement | ACV, ACA, DCV, DCA, ohms, continuity beeper, Hz, Capacitance, Diode, Data hold. |
A/D counts no. | 6000 counts |
Range selection | Smart function, auto range or manual range selecting. |
Smart function | ” V ” function can select ACV, DCV automatically with auto range. ” Ω ” function can select the Resistance, Diode, Continuity beeper, Capacitance automatically with auto range. ” 10A ” ” mA ” function can measure ACA, DCA with auto range. |
Data hold | To freeze the display reading on the LCD display. * Available for auto range only |
Power On/Off management | If meter is not operated within 3 minutes will auto power switch off |
Polarity | Automatic Switching, ” – ” indicates negative polarity. |
Zero adjustment | Automatic |
Power Supply | Green power : Power from the handy generator, battery is no need. Battery power : DC3V battery ( CR-2032 ) x 2 PCs |
Accessories included | Red and Black Test Leads 1 Set Instruction Manual |
Optional Accessories | Full line adapters : * ACA/DCA current adapter : CA-502, CA-203, CA-501 * ACA current adapter : CA-201 * Pressure adapter : PS-403 * Light adapter : LX-02 * EMF adapter : EMF-824 * Sound level adapter : SL-406 * High voltage probe : HV-40 |
Electrical Specifications (23± 5 ) |
---|
DC/AC Voltage * auto range | |
Range | 6 V /60 V/600 V |
Resolution | 0.001 V /0.01 V/0.1 V |
Accuracy
|
DCV : ± ( 1 % + 2d ) |
ACV : ± ( 1.2 % + 5d ) | |
Input impedance | 10 M ohm. |
Over load protection | AC/DC 600 V. |
Remark | * The input impedance is 10 Mega ohm * ACV specification be tested on sine wave 50/60 Hz. * For smart function ,the ACV start measurement voltage is larger than 400 mV ± 100 mV. |
DC/AC Current * auto range | ||
Range
|
mA range | 600 mA/60 mA |
10 A range | 10A | |
Resolution
|
mA range | 0.1 mA/0.01 mA |
10 A range | 0.01 A | |
Accuracy
|
mA range | ± ( 1.2% + 2d ) |
10 A range | ± ( 1.5% + 2d ) | |
Over load protection
|
mA range | 630 mA fuse |
10 A range | 10 A fuse | |
Remark | * ACA specification be tested on sine wave 50/60 Hz * For smart function ,the ACA start measurement is 10 A range : 1.50 A. mA range : 1.50 mA |
OHMS * auto range | |
Range | 600/6 K/60 K/600 K/6 M ohm |
Resolution | 0.1/1/10/100/1 K ohm |
Accuracy | ± ( 1% + 3d ) |
Over load protection | ± 350 DCV, 350 ACV |
Capacitance * auto range | |
Range | 6 nF/60 nF/600 nF/6 uF/60 uF |
Resolution | 0.001 nF/0.01 nF/0.1 nF/0.001 uF/ 0.01 uF |
Accuracy | ± ( 3% + 5d ) |
Remark | Discharge capacitor before testing. |
Frequency | |
Range | 40 Hz to 1 KHz. |
Resolution | 1 Hz. |
Accuracy | ± ( 0.3% + 2d ) |
Input impedance | 10 M ohm. |
Over load protection | AC/DC 600 V |
Diode | |
Short/non conductance, good/defect test. |
Continuity | |
If measuring resistance is less than 10 ohm, the beeper will sound . |
Lutron DM-9983G – Datasheet
KARYA MANDIRI TECHINDO adalah Supplier Lutron DM-9983G Green Power Smart Multimeter dan juga menjual Brand Lutron. Lihat produk kami lainnya di sini JSI, SGI, SMG atau hubungi kami lewat Whatsapp 0821-3010-0456 atau via email [email protected].