Product Description
TDS-100F Ultrasonic Flow Meter
The type of liquid measured by the flow meter can be various kinds of fluids such as drinking water, waste water, sludge water, milk, chemical liquids, sugar water, alcohol, oil etc.
Ultrasonic Flow Meter TDS-100F measures the flow rate of liquids by the ultrasonic method. It has an airtight unit protection class IP65.
Specification TDS-100F Ultrasonic Flow Meter
Linearity | Better than ±1%. |
Accuracy | ±1% of reading at rates >0.6 ft/s (0.2m/s). Assume a fully developed flow profile. |
Repeatability | ±0.2%. |
Velocity | ±0.03 ~ ±105 ft/s (±0.01 ~ ±30 m/s), bi-directional |
Measurement Period | 0.5s |
Display | LCD with backlight. 2×20 letters. |
Keypad | 4×4-key membrane keypad with tactile feedback |
Units | English (U.S.) or metric. |
Outputs | Analogue output: 4-20mA or 0-20mA current output. Impedance 0~1kW. Accuracy 0.1%. . |
Isolated OCT output: for frequency output (0~9,999Hz), alarm driver, or totaliser pulse output, ON/OFF control, etc. Relay output 1A@125VAC or 2A@30VDC. For ON/OFF control, alarm driver, totaliser output, etc. |
|
Internal Alarm (Buzzer): user programmable. External Alarm Driver: alarm signal can be transmitted to Relay or OCT output terminals to drive an external alarm. |
|
RS-232 serial port. | |
Input | Five channel 4-20mA current inputs for signals such as temperature, pressure, liquid level, and etc.. Accuracy 0.1%. Two of the five input channels are wired to terminal blocks. The remaining three channels are optional. |
Enclosure | Die-cast aluminum enclosure. |
Protection Class: IP65 (NEMA 4X). | |
Size: 9.88×7.56×3.15 (251x192x80mm3) for standard version | |
Clamp-on | S2-type: for pipe size (DN15~DN100mm) |
M2-type: for pipe size (DN50~DN700mm) | |
L2-type: for pipe size (DN300~DN6,000mm) | |
Liquid Types | Virtually all commonly used clean liquids. |
Liquids with small quantity of tiny particles may also be applicable. Particle size should be less than 75um, particle concentration less than 10,000ppm. | |
Liquids should contain no or very minor air bubbles. | |
Examples are chilled/hot water, sea water, waste water, chemical liquids, oil, crude oil, alcohol, beer, etc. | |
Liquid Temp | (0C – 160C) for clamp-on transducer. Higher temperatures can be accommodated. Consult us for assistance. |
(0C – 160C) for wetted transducer. | |
Pipe Size | 1 ~ 240 (DN15mm ~ DN6,000mm). |
Pipe Material | All metals, most plastics, fiber glass, etc. Allow pipe liner. |
Cable | Shielded transducer cable. Standard length 15 (5m). Can be extended to 1640 (500m). Contact us for longer cable requirement. |
Power | AC: 240V DC: 8VDC~36VDC |
Power consumption: < 2W | |
Weight | Standard main unit: 6.6lb (3kg) |
TDS-100F – Manual
Produk asli Kami distributor langsung Flow Meter . Harga murah dan berkualitas bergaransi tentunya. dapat di kirim ke seluruh wilaya indonesia.
Dalam pengiriman produk yang pelanggan beli, sebelumnya sudah kami cek untuk memastikan produk dalam keadaan baik dan siap kirim.