Hanna HI-801-02 Iris Visible Spectrophotometer

Hanna HI-801-02 Iris Visible Spectrophotometer

The HI801 iris is a sleek and intuitive spectrophotometer that allows for measurement of all wavelengths of visible light. Customise your methods, take a wide range of measurements, and feel confident in your testing accuracy with iris.

  • Power Supply 15 VDC power adapter; 10.8 VDC Li-Ion rechargeable battery
  • Battery Type/Life 3000 measurements or 8 hours
  • Environment 0 to 50 °C (32 to 122 °F); 0 to 95% RH

Description

Hanna HI-801-02 Iris Visible Spectrophotometer

Karya Mandiri Techindo has a wide range of Hanna Instruments products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..

The HI801 iris is a sleek and intuitive spectrophotometer that allows for measurement of all wavelengths of visible light.

Customize your methods, take a wide range of measurements, and feel confident in your testing accuracy with iris.

  • iris features precise wavelength selection between 340 nm to 900 nm for complete method compliance and accuracy that is necessary in industries like professional laboratories, water treatment facilities, wineries, and more
  • Results are consistent and accurate regardless of throughput with the high quality and uniquely designed optics system
  • Customization options include multiple cuvette shapes and sizes, custom calibration curves, and methods

Superior design for superior results

iris can test a wide variety of analytical measurements and is capable of measuring in a spectral range of 340 nm to 900 nm.

With the compact design of its advanced optical system, iris can be used in almost any sized space while providing accurate and consistent results. The split beam optical system allows iris to automatically compensate for any drift in light source, resulting in superior accuracy.

No need for measurement conversions

Whether you are testing for chlorine or running enzymatic assays, our spectrophotometer will conveniently display results in the units that matter most to you. iris can measure in transmittance, absorbance, and concentration based on your need.

The convenience of pre-programmed methods with the option to expand

iris comes pre-programmed with more than 80 commonly used chemical analysis methods to help you get started. Simply update these methods by connecting to a computer or flash drive.

Customize your iris with up to 100 personal methods. iris will guide you through the method creation process step-by-step. For added versatility, each method can include up to 10 calibration points, five different wavelengths, and up to five reaction timers.

Easily access your favorite methods directly from the home screen to save time.

Built in timers make make measuring seamless. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between measurements and users. If you get stuck, the tutorial mode will walk you through the steps.

Change sample size easily

With our universal cuvette holder and auto-recognition feature, cuvette sizes can be changed when needed. The programmed cuvette size will be displayed on the screen every time you test to ensure that the proper path length is being used by the meter when calculating measurements for correct results.

RoundVialSquare
sidesdata loggingbasic mode
Worry free replacements

iris uses a tungsten-halogen lamp for greater energy efficiency, longer service life, and improved light quality for a wide variety of wavelengths. Replacement lamps are shipped pre-aligned and ready for installation so that you can get back to testing.

Designed for dynamic environments

iris’ compact profile and long-lasting battery make it easy to set up anywhere in your lab. The rechargeable lithium ion battery lasts for 3,000 measurements, or 8 hours – well over a full day of use out in the field.

Quality data without the hassle

Export your results with a USB drive or direct PC link organized by sample ID, method, or date range. Save data as a .pdf or .csv for maximum data integrity or flexibility – all without the use of specialized software.

Menu navigation that makes sense

Quickly navigate between screens with custom keys, and access your favorite methods directly from the home screen with our “favorite methods” feature.

Sort and share your data

Save data as a .pdf or .csv for maximum data integrity or flexibility. Have the freedom to choose the file format that’s best for you.

All of your important information is easily visible

With a 6” display, the screen is large and easy to read. The high contrast makes every character on the display stand out even during outdoor use. The wide viewing angle allows for measurements to be seen from far away, so while working around the lab it is not necessary to hover over the meter to see the measurements.

Zero resistance with a capacitive touch pad

Menu buttons are part of the display. Built to be fully sealed and easy to clean, the meter recognizes key touches even through gloves.

Specifications Hanna HI-801-02 Iris Visible Spectrophotometer

 
SKUHI801-02
Product Nameiris Visible Spectrophotometer – HI801
Quote RequiredYes
pH Range6.5 to 8.5 pH
pH Resolution0.1 pH
pH Accuracy±0.1 pH
pH MethodAdaptation of the Phenol Red method
Dissolved Oxygen Range0.0 to 10.0 mg/L (as O2 )
Dissolved Oxygen Resolution0.1 mg/L
Dissolved Oxygen Accuracy±0.4 mg/L ±3% of reading
Dissolved Oxygen Measurement MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method
Absorbance Range0.000 to 3.000 Abs
Absorbance Resolution0.001 Abs
Absorbance Accuracy5 mAbs at 0.000-0.500 Abs 1% at 0.500-3.000 Abs
Alkalinity Range0 to 500 mg/L (as CaCO3 )
Alkalinity Resolution1 mg/L
Alkalinity Accuracy±5 mg/L ±5% of reading
Alkalinity MethodColorimetric Method
Seawater Alkalinity Range0 to 300 mg/L (as CaCO3 )
Seawater Alkalinity Resolution1 mg/L
Seawater Alkalinity Accuracy±5 mg/L ±5% of reading
Seawater Alkalinity MethodColorimetric Method
Aluminum Range0.00 to 1.00 mg/L (as Al3+)
Aluminum Resolution0.01 mg/L
Aluminum Accuracy±0.04 mg/L ±4% of reading
Aluminum MethodAdaptation of the aluminon method.
Ammonia RangeLow Range
Ammonia ResolutionLow and Medium Range
Ammonia AccuracyLow Range
Ammonia MethodAdaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler method.
Anionic Surfactants Range0.00 to 3.50 mg/L (as SDBS)
Anionic Surfactants Resolution0.01 mg/L
Anionic Surfactants Accuracy±0.04 mg/L ±3% of reading
Anionic Surfactants MethodAdaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 5540C, Anionic Surfactants as MBAS
Bromine Range0.00 to 8.00 mg/L (as Br2 )
Bromine Resolution0.01 mg/L
Bromine Accuracy±0.08 mg/L ±3% of reading
Bromine MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method
Calcium Range0 to 400 mg/L (as Ca2+)
Calcium Resolution1 mg/L
Calcium Accuracy±10 mg/L ±5% of reading
Calcium MethodAdaptation of the Oxalate method
Carbon Dioxide Range0.00 to 2.00 mg/L (as ClO2 )
Carbon Dioxide Resolution0.01 mg/L
Carbon Dioxide Accuracy±0.10 mg/L ±5% of reading
Carbon Dioxide MethodAdaptation of the Chlorophenol Red method
Chemical Oxygen Demand RangeLow Range
Chemical Oxygen Demand Resolution1 mg/L
Chemical Oxygen Demand AccuracyLow Range
Chemical Oxygen Demand MethodAdaptation of the USEPA 410.4
Chloride Range0.0 to 20.0 mg/L (as Cl)
Chloride Resolution0.1 mg/L
Chloride Accuracy±0.5 mg/L ±6% of reading
Chloride MethodAdaptation of the mercury(II) thiocyanate method
Chlorine Dioxide Range0.00 to 2.00 mg/L (as ClO2 )
Chlorine Dioxide Resolution0.01 mg/L
Chlorine Dioxide Accuracy±0.10 mg/L ±5% of reading
Chlorine Dioxide MethodAdaptation of the Chlorophenol Red method
Free Chlorine RangeUltra Low Range
Free Chlorine ResolutionUltra Low Range
Free Chlorine AccuracyUltra Low Range
Total Chlorine RangeUltra Low Range
Total Chlorine ResolutionUltra Low Range
Total Chlorine AccuracyUltra Low Range
Chromium, Hexavalent RangeLow Range
Chromium, Hexavalent ResolutionLow Range
Chromium, Hexavalent AccuracyLow Range
Chromium, Hexavalent MethodAdaptation of the ASTM Manual of Water and Environmental Technology, D1687, Diphenylcarbohydrazide method
Color, Water Range0 to 500 PCU (Platinum Cobalt Units)
Color, Water Resolution1 PCU
Color, Water Accuracy±10 PCU ±5% of reading
Color, Water MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Colorimetric Platinum Cobalt method
Color, Maple Syrup Range0.00 to 100.00 %T
Color, Maple Syrup Resolution0.01 %T
Color, Maple Syrup Accuracy±3% of reading
Color, Maple Syrup MethodDirect measure
Copper RangeLow Range
Copper ResolutionLow Range
Copper AccuracyLow Range
Copper MethodAdaptation of the EPA method
Cyanide Range0.000 to 0.200 mg/L (as CN-)
Cyanide Resolution0.001 mg/L
Cyanide Accuracy±0.005 mg/L ±3% of reading
Cyanide MethodPyridine-Pyrazalone
Cyanuric Acid Range0 to 100 mg/L (as CYA)
Cyanuric Acid Resolution1 mg/L
Cyanuric Acid Accuracy±1 mg/L ±15% of reading
Cyanuric Acid MethodAdaptation of the turbidimetric method
Fluoride RangeLow Range
Fluoride ResolutionLow Range
Fluoride AccuracyLow Range
Fluoride MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method
Hardness, Total RangeLow Range
Hardness, Total Resolution1 mg/L
Hardness, Total AccuracyLow Range
Hardness, Total MethodAdaptation of the EPA recommended method 130.1
Hardness, Calcium Range0.00 to 2.70 mg/L (as CaCO3 )
Hardness, Calcium Resolution0.01 mg/L
Hardness, Calcium Accuracy±0.11 mg/L ±5% of reading
Hardness, Calcium MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Calmagite method
Hardness, Magnesium Range0.00 to 2.00 mg/L (CaCO3 )
Hardness, Magnesium Resolution0.01 mg/L
Hardness, Magnesium Accuracy±0.11 mg/L ±5% of reading
Hardness, Magnesium MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, EDTA Colorimetric method
Hydrazine Range0 to 400 µg/L (as N2H4 )
Hydrazine Resolution1 µg/L
Hydrazine Accuracy±4% of full scale reading
Hydrazine MethodAdaptation of the ASTM Manual of Water and Environmental Technology, method D1385, p-Dimethylaminobenzaldehyde method
Iodine Range0.0 to 12.5 mg/L (as I2 )
Iodine Resolution0.1 mg/L
Iodine Accuracy±0.1 mg/L ±5% of reading
Iodine MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method
Iron RangeLow Range
Iron ResolutionLow Range
Iron AccuracyLow Range
Iron MethodLow Range
Magnesium Range0 to 150 mg/L (as Mg2+)
Magnesium Resolution1 mg/L
Magnesium Accuracy±5 mg/L ±3% of reading
Magnesium MethodAdaptation of the Calmagite method
Manganese RangeLow Range
Manganese ResolutionLow Range
Manganese AccuracyLow Range
Manganese MethodLow Range
Molybdenum Range0.0 to 40.0 mg/L (as Mo6+)
Molybdenum Resolution0.1 mg/L
Molybdenum Accuracy±0.3 mg/L ±5% of reading
Molybdenum MethodAdaptation of the mercaptoacetic acid method
Nickel RangeLow Range
Nickel ResolutionLow Range
Nickel AccuracyLow Range
Nickel MethodLow Range
Nitrate Range0.0 to 30.0 mg/L (as NO3 – N)
Chromotropic Acid
Nitrate Resolution0.1 mg/L
Nitrate Accuracy±0.5 mg/L ±10% of reading
Chromotropic Acid
Nitrate MethodAdaptation of the cadmium reduction method
Chromotropic Acid
Nitrite RangeMarine Ultra Low Range
Nitrite ResolutionMarine Ultra Low Range
Nitrite AccuracyMarine Ultra Low Range
Nitrite MethodMarine Ultra Low Range
Nitrogen, Total RangeLow Range
Nitrogen, Total ResolutionLow Range
Nitrogen, Total AccuracyLow Range
Nitrogen, Total MethodChromotropic acid method
Oxygen, Scavenger RangeCarbohydrazide
Oxygen, Scavenger ResolutionCarbohydrazide
Oxygen, Scavenger AccuracyCarbohydrazide
Oxygen, Scavenger MethodAdaptation of the iron reduction method
Ozone Range0.00 to 2.00 mg/L (as O3 )
Ozone Resolution0.01 mg/L
Ozone Accuracy±0.02 mg/L ±3% of reading
Ozone MethodColorimetric DPD Method
Phosphate RangeLow Range
Phosphate ResolutionLow Range
Phosphate AccuracyLow Range
Phosphate MethodLow Range
Phosphorous, Acid Hydrolyzable Range0.00 to 1.60 mg/L (as P)
Phosphorous, Acid Hydrolyzable Resolution0.01 mg/L
Phosphorous, Acid Hydrolyzable Accuracy±0.05 mg/L or ±5% of reading
Phosphorous, Acid Hydrolyzable MethodAdaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method.
Phosphorous, Reactive RangeLow Range
Phosphorous, Reactive ResolutionLow Range
Phosphorous, Reactive AccuracyLow Range
Phosphorous, Reactive MethodAdaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20th edition, 4500-P E, ascorbic acid method.
Phosphorous, Total RangeLow Range
Phosphorous, Total AccuracyLow Range
Phosphorous, Total ResolutionLow Range
Phosphorous, Total MethodLow Range
Potassium RangeLow Range
Potassium ResolutionLow Range
Potassium AccuracyLow Range
Potassium MethodAdaptation of the Turbidimetric Tetraphenylborate method
Silica RangeLow Range
Silica ResolutionLow Range
Silica AccuracyLow Range
Silica MethodLow Range
Silver Range0.000 to 1.000 mg/L (as Ag)
Silver Resolution0.001 mg/L
Silver Accuracy±0.020 mg/L ±5% of reading
Silver MethodAdaptation of the PAN method
Sulfate Range0 to 150 mg/L (as SO42-)
Sulfate Resolution1 mg/L
Sulfate Accuracy±5 mg/L ±3% of reading
Sulfate MethodSulfate is precipitated with barium chloride crystals
Zinc Range0.00 to 3.00 mg/L (as Zn)
Zinc Resolution0.01 mg/L
Zinc Accuracy±0.03 mg/L ±3% of reading
Zinc MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method
Wavelength Range340 to 900 nm
Wavelength Resolution1 nm
Wavelength Accuracy±1.5 nm
Measurement ModesTransmittance (% T), absorbance (abs), concentration with choice of units (ppm, mg/L, ppt, ºf, ºe, ppb, meq/L, μg/L, PCU, Pfund, pH, dKH, ºdH, meq/kg or no measurement unit)
Wavelength Selectionautomatic, based on the selected method (editable for user methods only)
Optical Systemsplit beam sample and reference light detectors
Wavelength Calibrationinternal, automatic at power-on, visual feedback
Data Points Storedup to 9999 measured values
Export Capability.csv file format, .pdf file format
Connectivity(1) USB – A (mass storage host); (1) USB – B (mass storage device)
Power Supply15 VDC power adapter; 10.8 VDC Li-Ion rechargeable battery
Battery Type/Life3000 measurements or 8 hours
Environment0 to 50 °C (32 to 122 °F); 0 to 95% RH
Weight3 kg (6.6 lbs)
Dimensions155 x 205 x 322 mm (6.1 x 8.0 x 12.6″)
Ordering InformationHI801 is supplied with 22 mm sample cuvette and cap (4), 10 mm square, 13 mm round and 16 mm round cuvette adapters, cloth for wiping cuvettes, scissors, USB cable, lithium ion rechargeable battery, 115VAC to 15VDC power adapter, USB drive, instruction manual, and instrument quality certificate.

 

 

 

Hanna HI-801-02 – Manual

KARYA MANDIRI TECHINDO adalah Supplier Hanna HI-801-02 Iris Visible Spectrophotometer dan juga menjual Brand Hanna Instruments. Lihat produk kami lainnya di sini JSISGISMG atau hubungi kami lewat Whatsapp 0821-3010-0456 atau via email karyamandiritechindo@gmail.com.


 

Additional information

Brand

Hanna

Model

HI-801-02

Made In

Romania

TESTIMONI PELANGGAN

alhamdulillah pesanan sudah sampai di Bengkulu.Pengalaman order di karyamandiritechindo.com Respon cepat. Pengiriman Cepat dan Free, Aman & Terpercaya.

Ibu Natalia Dan Ria
PT. AGricinal

Terimakasih karyamandiritechindo.com, orderannya sudah sampai dengan selamat Kurir Syariftama Express sangat ramah

PT. Bumi Bangun Perkasa
Ibu Rizeki

Order yg kedua, seperti biasa produk sangat memuaskan dan pelayannya ramah, Terimakasih Pak Aji Amanda Semoga di orderan berikutnya tetap TOP

PT. Daruna

Puas banget belanja di karyamandiritechindo.com. pengiriman cepat kualitas produk mantap.

PT. Niaga Andalan Serayat

BUAT PERMINTAAN HARGA