Product Description
Hanna HI-96715 Ammonia Medium Range Portable Photometer
Karya Mandiri Techindo has a wide range of Hanna Instruments products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..
The HI96715 portable photometer is for the measurement of ammonia (as NH3-N) in freshwater samples. Hanna’s portable photometers feature an advanced optical system; the combination of a light emitting diode (LED), a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check™ feature utilizes ready-made standards traceable to a NIST Standard for performance verification and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.
Features at-a-glance
CAL Check™ – Allows for performance verification and calibration of the meter using a CAL Check NIST traceable secondary standard.
GLP – Records the date of the last user calibration performed.
Built in timer – Allows the use of a timer to ensure the appropriate 3 minutes and 30 seconds reaction time is used for the chemical reaction. At the end of the timer countdown the meter will automatically take the reading. This feature ensures consistency across multiple users.
Indexing indent on meter – The meter has an indent that allows for a lock and key fit with the cuvette cap. This ensures that the cuvette is indexed consistently (same position) in order to maintain the same path length for accurate results.
Cooling Lamp Indicator – It is necessary to maintain a consistent temperature of the optical components in order to maintain a narrow wavelength band of light. This photometer has a cooling lamp indicator that is displayed for a short period of time before each measurement in order to allow the components to cool and obtain the highest accuracy possible.
Error messages – Messages on display alerting to problems including no cap, over range and under range readings, and light source error.
Auto-shut off – Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally not turned off.
Battery status indicator
The instrument has a battery level indicator to display reaming life as follows:
- 3 lines for 100 % capacity
- 2 lines for 66 % capacity
- 1 line for 33 % capacity
- Battery icon blinks when the capacity is less than 10 %.
Units of measure – Appropriate unit of measure is displayed along with reading.
Present naturally in surface and wastewaters, ammonia is largely present from deamination of organic nitrogen-containing compounds and hydrolysis of urea. Ammonia may also be present from water treatment processes that utilize chloramines for disinfection, where ammonia is added to the water to react with chlorine. Ammonia is less likely to appear in groundwater due to adsorption to soil particles.
The HI96715 uses an adaptation of the ASTM Manual of Water and Environmental Technology, D1426-93 Nessler method to measure ammonia-nitrogen concentrations in the 0.00 to 9.99 mg/L (ppm) range. When the Nessler reagent is added to samples containing ammonia, the sample will turn a yellow hue; the greater the concentration, the deeper the color. The associated color change is then colorimetrically analyzed according to the Beer-Lambert Law. This principle states that light is absorbed by a complementary color, and the emitted radiation is dependent upon concentration. For mid range levels of ammonia, a narrow band interference filter at 466 nm (blue) allows only blue light to be detected by the silicon photodetector. As the change in color of the reacted sample increases, absorbance of the specific wavelength of light also increases, while transmittance decreases.
The HI96715 is available as a kit (HI96715C) which includes
- Portable Photometer
- Sample cuvettes (2)
- Caps (2)
- CAL Check™ standards with certificate
- Cuvette cleaning cloth
- Rugged carrying case
- Thermoformed insert for meter and accessories
*Reagents ordered separately
CAL Check™ standards with certificate
The HI96715-11 CAL Check™standards are used for calibration and performance verification of photometers with the CAL Check™ function.
Supplied with Certificate of Analysis
- Lot number
- Expiration date
- Standard value @ 25 °C
- Reference meter NIST traceable
Provided storage containers
- Light tight
- Protects from accidental breakage
Specifications Hanna HI-96715 Ammonia Medium Range Portable Photometer
SKU | HI96715-web |
---|---|
Product Name | Ammonia Medium Range Portable Photometer – HI96715 |
Quote Required | Yes |
Ammonia Range | 0.00 to 9.99 mg/L (ppm) (as NH₃-N) |
Ammonia Resolution | 0.01 mg/L |
Ammonia Accuracy | ±0.05 mg/L ±5% of reading |
Ammonia Method | adaptation of the ASTM Manual of Water and Environmental Technology, D1426-93, Nessler method |
Photometer/Colorimeter Light Source | light emitting diode |
Photometer/Colorimeter Light Detector | silicon photocell with narrow band interference filter @ 466 nm |
Battery Type/Life | 9V battery |
Automatic Shut-Off | after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Weight | 360g (12.7oz.) |
Dimensions | 193 x 104 x 69 mm (7.6 x 4.1 x 2.7”) |
Ordering Information | HI96715 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate and instruction manual. |
Hanna HI-96715 – Manual
KARYA MANDIRI TECHINDO adalah Supplier Hanna HI-96715 Ammonia Medium Range Portable Photometer dan juga menjual Brand Hanna Instruments. Lihat produk kami lainnya di sini JSI, SGI, SMG atau hubungi kami lewat Whatsapp 0821-3010-0456 atau via email [email protected].