- Same as basic probe but with logging capability
- Logs data independent of HI9829 meter
- Operates on 4 “AA” batteries for up to 70 days*
- Stores up to 140,000 single parameter readings or 35,000 for all parameters
- Logs data from 1 second to 3 hours
- Choose to be supplied with EC or EC/Turbidity sensor
- Supplied with USB cable for direct connection to Window’s compatible PC
Waterproof Protection – The water quality meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1 m for up to 30 minutes. The probe features an IP68 rating for continuous immersion in water.
Backlit Dot Matrix LCD Display – The HI9829 features a backlit graphic LCD with on-screen help and the capability to display up to twelve parameters simultaneously. The graphic display allows for the use of virtual keys to provide for an intuitive user interface.
Intuitive Keypad – The fitted rubber keypad has dedicated keys for power, backlight, up/down arrows, help and alphanumeric characters. The meter also features two virtual soft keys that navigate the user through the configuration of each parameter, meter setup and logging of data. The interface is intuitive for any user’s level of experience.
Dedicated Help Key – Contextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting/option being viewed.
Auto-sensor Recognition – The probe and meter automatically recognize the sensors that are connected. Any ports not used on the probe will not have the parameter displayed or be configurable.
Automatic temperature compensation – Integrated temperature sensor allows for automatic temperature compensation of pH, conductivity, and dissolved oxygen measurements.
Automatic Barometric Pressure Compensation – The meter features a built-in barometer with user-selectable units for dissolved oxygen pressure compensation.
Quick Calibration – Quick Calibration provides a speedy, single point calibration for pH, conductivity, and dissolved oxygen. Standard calibration options are available including pH up to three points, Conductivity at one point and dissolved oxygen up to two points.
GLP Data – HI9829 includes a GLP feature that allows users to view calibration data and calibration expiration information at the touch of a key. Calibration data includes the date, time, buffers/standards used for calibration, and slope characteristics.
Data Logging – The HI9829 allows users to store up to 44,000 continuous or log-on-demand samples with logging intervals from one second to three hours.
Graphing Capability – Trend graphing with sample date and time stamp may be viewed on the display or transferred to a pc.
PC Connectivity – Logged data can be transferred to a Windows-compatible PC with the included HI7698291 USB adapter and HI929829 software.
Long Battery Life – The display of the meter has a battery icon indicator to show the remaining power. The meter is supplied with four 1.5V “C “ NiMH rechargeable batteries that provide up to 140 hours of battery life*
Rugged thermoformed carrying case – The HI9829 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The inside compartment of the carrying case is thermoformed to securely hold and protect all of the components.
* Without GPS or turbidity measurements
Specifications Hanna HI-9829 Multiparameter with optional GPS
HI-9829 specification with/without GPS |
|
|
Temperature Compensation |
|
Automatic from -5 to 55°C |
Models with GPS |
|
12 Channel Receiver, 10m range |
Logging memory from meter |
|
44,000 records |
Logging interval |
|
1 second to 3 hours |
Computer interface |
|
USB (with HI-929829) |
FastTracker™ TAG ID |
|
Yes |
Waterproof protection |
|
IP67 |
Environment |
|
0 to 50°C, RH 100% |
Power supply |
|
1.5 V Alkaline C cells (4)/1.2V NiMH rechargeable C Cells (4) USB, 12V power adapter |
Dimensions |
|
221 x 115 x 55mm |
Weight |
|
750g |
Maximum Probe Immersion |
|
Depth – 20 metres |
HI-9829 parameter specifications
pH Range |
|
0.00 to 14.00 pH |
pH Resolution |
|
0.01 pH |
pH Accuracy |
|
±0.02 pH |
pH Calibration |
|
automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer |
mV Range |
|
±600.0 mV |
mV Resolution |
|
0.1 mV |
mV accuracy |
|
±0.5 mV |
ORP Range |
|
±2000 mV |
ORP Resolution |
|
0.1 mV |
ORP Accuracy |
|
±1.0 mV |
ORP Calibration |
|
automatic at one custom point (relative mV) |
EC Range |
|
0 to 200 mS/cm (absolute EC up to 400 mS/cm) |
EC Resolution |
|
Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm, Automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm, Automatic (mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm |
EC Accuracy |
|
±1% of reading or ±1 µS/cm whichever is greater |
EC Calibration |
|
automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point |
TDS Range |
|
0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor) |
TDS Resolution |
|
Manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L), Automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L), Automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L) |
TDS Accuracy |
|
±1% of reading or ±1 ppm (mg/L), whichever is greater |
TDS Calibration |
|
based on conductivity or salinity calibration |
Resistivity Range |
|
0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm |
Resistivity Resolution |
|
dependent on resistivity reading |
Resistivity Calibration |
|
based on conductivity calibration |
Salinity Range |
|
0.00 to 70.00 PSU |
Salinity Resolution |
|
0.01 PSU |
Salinity Accuracy |
|
±2% of reading or ±0.01 PSU whichever is greater |
Salinity Calibration |
|
based on conductivity calibration |
Seawater σ Range |
|
0.0 to 50.0 σt, σ0, σ15 |
Seawater σ Resolution |
|
0.1 σt, σ0, σ15 |
Seawater σ Accuracy |
|
±1 σt, σ0, σ15 |
Seawater σ Calibration |
|
based on conductivity or salinity calibration |
Ammonium-Nitrogen Range |
|
0.02 to 200.0 ppm Am (as NH4 +-N) |
Ammonium-Nitrogen Resolution |
|
0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm |
Ammonium-Nitrogen Accuracy |
|
±5 % reading or 2 ppm |
Ammonium-Nitrogen Calibration |
|
1 or 2 point, 10 ppm and 100 ppm |
Chloride Range |
|
0.6 to 200.0 ppm Cl (as Cl- ) |
Chloride Resolution |
|
0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm |
Chloride Accuracy |
|
±5 % of reading or 2 ppm |
Chloride Calibration |
|
1 or 2 point, 10 ppm and 100 ppm |
Nitrate-Nitrogen Range |
|
0.62 to 200.0 ppm Ni (as NO3 – -N) |
Nitrate-Nitrogen Resolution |
|
0.01 ppm to 1 ppm 0.1 ppm to 200 ppm |
Nitrate-Nitrogen Accuracy |
|
±5 % of reading or 2 ppm |
Nitrate-Nitrogen Calibration |
|
1 or 2 point, 10 ppm and 100 ppm |
Turbidity Range |
|
0.0 to 99.9 FNU; 100 to 1000 FNU |
Turbidity Resolution |
|
0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU |
Turbidity Accuracy |
|
±0.3 FNU or ±2 % of reading, whichever is greater |
Turbidity Calibration |
|
Automatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom |
DO Range |
|
0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L) |
DO Resolution |
|
0.1%; 0.01 ppm (mg/L) |
DO Accuracy |
|
0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3% of reading |
DO Calibration |
|
automatic one or two points at 0 and 100% or one custom point |
Atmospheric Pressure Range |
|
450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
Atmospheric Pressure Resolution |
|
0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
Atmospheric Pressure Accuracy |
|
±3 mm Hg within ±15°C from the temperature during calibration |
Atmospheric Pressure Calibration |
|
automatic at one custom point |
Ordering Information |
|
The HI-9829 is supplied with a HI-710140 hard carrying case, HI-7612VDC adapter, HI-7698292 probe maintenance kit, HI-929829 PC application software, HI-7698291 USB cable (PC to meter), HI-710045 power supply cable, HI-710046 cigarette lighter power cable, HI-9829-25 quick calibration solution, HI-920005 iButton with holder (5), HI-7609829-1 pH/ORP sensor, HI-7609829-2 galvanic DO sensor, HI-7609829-3 EC sensor, HI-7698290 short calibration beaker, HI-7698295 short protective weighted shield, NiMH rechargeable “C” cell batteries (4), 12VDC power adapter, and instruction manual.
Probes selected with turbidity option will include the HI-7609829-4 EC/turbidity sensor, HI-7698293 long calibration beaker and HI-7698296 long protective weighted shield in place of the EC sensor, short calibration beaker and short protective shield. Probes selected with turbidity option will also include turbidity calibration solutions (230 ml); HI-9829-16 0 FNU, HI-769829-17 20 FNU, and HI-9829-18 200 FNU. |