Product Description
Lutron VB-8209SD Vibration Meter
Application : For industrial vibration monitoring: All industrial machinery vibrates. The level of vibration is a useful guide to machine condition. Poor balance, misalignment & looseness of the structure will cause the vibration level increase, it is a sure sign that the maintenance is needed.
Features Lutron VB-8209SD Vibration Meter
- Frequency range 10 Hz – 1 kHz, sensitivity relative meet ISO 2954.
- Frequency range 10 Hz – 5 kHz for other Application example ISO 2372..
- Professional vibration meter supply with vibration sensor & magnetic base,full set.
- Metric & Imperial display unit
- Acceleration, Velocity, Displacement measurement
- RMS, Max hold, Peak value measurement.
- Max. Hold reset button, Zero button.
- Wide frequency range.
- Data hold button to freeze the desired reading.
- Memory function to record maximum and minimum reading with recall.
- Separate vibration probe with magnetic base, easy operation.
- Real time SD memory card Datalogger, it Built-in Clock and Calendar,real time data recorder , sampling time set from 1 second to 3600 seconds
- Manual datalogger is available ( set the sampling time to 0 ), during execute the manual datalogger function, it can set the different position ( location ) No. ( position 1 to position 99 ).
- SD card capacity : 1 GB to 16 GB.
- LCD with green light backlight, easy reading.
- Can default auto power off or manual power off.
- Data hold, record max. and min. reading.
- Microcomputer circuit, high accuracy
- Power by UM3/AA ( 1.5 V ) x 6 batteries or DC 9V adapter
- RS232/USB PC COMPUTER interface.
Specifications Lutron VB-8209SD Vibration Meter
Circuit | Custom one-chip of microprocessor LSI circuit. | |||
Display
|
LCD size : 52 mm x 38 mm
LCD with green backlight ( ON/OFF ). |
Measurement | Velocity, Acceleration, Displacement | |||
Function
|
Acceleration, Velocity : RMS, Peak, Max Hold
Displacement : p-p ( peak-peak ), Max Hold p-p. |
Unit
|
Measurement | Metric | Imperial | |
Acceleration | m/s^2, g | ft/s^2, | ||
Velocity | mm/s, cm/s | inch/s | ||
Displacement | mm | inch/s |
Frequency range
|
10 Hz to 1 KHz
* Sensitivity relative during the the frequency range meet ISO 2954 Refer to table 1, page 2810 Hz to 5 KHz : * for other aplication example ISO 2372 – Vibration severity application Refer to table 1, page 28 |
Electrical Specifications (23±5 ℃ )
Acceleration ( RMS, Peak, Max Hold ) | |
Unit | m/s^2 |
Range | 0.5 to 199.9 m/s^2 |
Resolution | 0.1 m/s^2 |
Accuracy | ±( 5 % + 2 d ) reading @ 160 Hz, 80 Hz, 23 ± 5 ℃ |
Calibration Point | 50 m/S^2 ( 160 Hz ) |
Unit | g @ 1 g = 9.8 m/s^2 |
Range | 0.05 to 20.39 G |
Resolution | 0.01 G |
Accuracy | ±( 5 % + 2 d ) reading @ 160 Hz, 80 Hz, 23 ± 5 ℃ |
Calibration Point | 50 m/S^2 ( 160 Hz ) |
Unit | ft/s^2 |
Range | 2 to 656 ft/s^2 |
Resolution | 1 ft/s^2 |
Accuracy | ±( 5 % + 2 d ) reading @ 160 Hz, 80 Hz, 23 ± 5 ℃ |
Calibration Point | 50 m/S^2 ( 160 Hz ) |
Velocity ( RMS, Peak, Max Hold ) | |
Unit | mm/s |
Range | 0.5 to 199.9 mm/s |
Resolution | 0. 1 mm/s |
Accuracy | ±( 5 % + 2 d ) reading @ 160 Hz, 80 Hz, 23 ± 5 ℃ |
Calibration Point | 50 mm/s ( 160 Hz ) |
Unit | cm/s |
Range | 0.05 to 19.99 cm/s |
Resolution | 0. 01 cm/s |
Accuracy | ±( 5 % + 2 d ) reading @ 160 Hz, 80 Hz, 23 ± 5 ℃ |
Calibration Point | 50 mm/s ( 160 Hz ) |
Unit | inch/s |
Range | 0.02 to 7.87 inch/s |
Resolution | 0.01 inch/s |
Accuracy | ±( 5 % + 2 d ) reading @ 160 Hz, 80 Hz, 23 ± 5 ℃ |
Calibration Point | 50 mm/s ( 160 Hz ) |
Displacement ( p-p, Max Hold p-p ) | |
Unit | mm |
Range | 1.999 mm |
Resolution | 0.001 mm |
Accuracy | ±( 5 % + 2 d ) reading @ 160 Hz, 80 Hz, 23 ± 5 ℃ |
Calibration Point | 0.141 mm ( 160 Hz ) |
Unit | inch |
Range | 0.078 inch |
Resolution | 0.001 inch |
Accuracy | ±( 5 % + 2 d ) reading @ 160 Hz, 80 Hz, 23 ± 5 ℃ |
Calibration Point | 0.141 mm ( 160 Hz ) |
Lutron VB-8209SD – Datasheet
Produk asli Kami distributor langsung Lutron. Harga murah dan berkualitas bergaransi tentunya. dapat di kirim ke seluruh wilaya indonesia.