Product Description
Tenmars TM-2011 Clamp Meter
Application
Features Tenmars TM-2011 Clamp Meter
-
AC current (IAC).
-
AC voltage (VAC).
-
DC voltage (VDC).
-
Resistance.
-
Continuity Test.
-
Diode test.
Specification Tenmars TM-2011 Clamp Meter
-
Display:3 ½ LCD with maximum reading 3999 units plus decimal point signs.
-
Sample rate:2 times/sec.
-
Conversion mode:mean value
-
Jaws opening:50mm
-
Max conductor size:52mm
-
Dimension: 266mm(L)x93mm(W)x47mm(H).
-
Weight:about 580g. (Including battery)
AC Curren
|
|||
Range
|
Resolution
|
Accuracy
(50~60 Hz) |
Overload Protection
|
400A
|
0.1A
|
±(2.0%+5)
|
660A rms
(60 second) |
660A
|
1A
|
±(2.5%+5)
|
DC Voltage
|
||||
Range
|
Resolution
|
Accuracy
|
Input
impedance |
OverloadProtection
|
400V
|
0.1V
|
±(0.5%+3dgt)
|
10MΩ
|
DC 1000V
AC750Vrms
|
1000V
|
1V
|
±(0.8%+3dgt)
|
AC Voltage
|
||||
Range
|
Resolution
|
Accuracy
|
Input
impedance |
OverloadProtection
|
400V
|
0.1V
|
±(0.5%rdg+3 dgt)
|
10MΩ
|
DC 1000V
AC750Vrms
|
750V
|
1V
|
±(0.8%rdg+3 dgt)
|
Resistance
|
||||
Range
|
Resolution
|
Accuracy
|
Max.Open
Loop voltage |
Overload Protection
|
400Ω
|
0.1Ω
|
±(1.0rdg+5dgt)
|
About 3.0VDC
|
DC 1000V
AC750Vrms
|
4000Ω
|
1Ω
|
±(1.0rdg+3dgt)
|
Continuity and Diode test
|
|||
Range
|
Buzzer
|
Max.Open
Loop voltage |
Overload Protection
|
![]() ![]() |
Activated
for R<40Ω |
About 3.0VDC
|
DC 1000V
AC750Vrms |
Frequency” tests
|
||||
Range
|
Resolution
|
Accuracy
|
Max.Open
Loop voltage |
Overload Protection
|
660Hz
|
0.1Hz
|
±(0.5%rdg+3 dgt)
|
About 3.0Vms
|
DC 1000V
AC750Vrms
|
6.6Hz
|
1Hz
|
|||
66KHz
|
10Hz
|
|||
100KHz
|
100Hz
|
Tenmars TM-2011 – Datasheet
Produk asli Kami distributor langsung Tenmars . Harga murah dan berkualitas bergaransi tentunya. dapat di kirim ke seluruh wilayah indonesia.