Product Description
Fluke 1587 FC Insulation Tester Multimeter
Karya Mandiri Techindo has a wide range of Fluke products – search by type, or model, or filter by brand to find the one you are after. If you still can’t find it contact us..
The high-performance 2-in-1 insulation digital multimeter
This insulation multimeter is the combination of a digital insulation tester that comes supplied with a full-featured, True RMS digital multimeter in a single compact, handheld unit, which enables maximum versatility for troubleshooting and preventative maintenance.
Features Fluke 1587 FC Insulation Tester Multimeter
- PI/DAR timed ratio tests
- Live circuit detection prevents insulation test if voltage >30 V is detected for added user protection
- VFD low-pass filter for accurate motor drive measurements
- Auto-discharge of capacitive voltage for added user protection
- Insulation test of 0.01 MΩ to 2 GΩ
- Insulation test voltages of 50, 100, 250, 500 V for many applications
- AC/DC voltage, DC millivolts, AC/DC milliamps, resistance (Ω), continuity
- Capacitance, diode test, temperature, Min/Max, frequency (Hz)
- Auto power off to save battery power
- CAT III 1000 V, CAT IV 600 V measurement category
- Large display with backlight
- Safety first. Keep yourself out of harm’s way by monitoring your test measurements remotely
- Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone
- Quickly find problems by saving and comparing measurements over time on a wireless device
Keep yourself safe. Find hidden problems faster. Put the paperwork down
Fluke Connect and this insulation multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily – all at a safe distance.
Add diagnostics with Fluke Connect
Fluke Connect is enabled so you can download the free application to your smartphone and gain additional functions, including:
- Safety first. Keep yourself out of harm’s way by monitoring your test measurements remotely
- Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone
- Quickly find problems by saving and comparing measurements over time on a wireless device
- PI/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems faster
- Memory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over time
- Temperature compensation to establish accurate baselines and relevant historical comparisons
- Historical tracking and trending of assets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke Connect® Assets (sold separately)
- Provides memory storage through Fluke Connect Measurements to eliminate the need to write down results
- Includes live circuit detection to prevent insulation test if voltage >30 V is detected
- Provides automated temperature compensation to establish accurate baselines
- Incorporates VFD low-pass filter for accurate variable frequency motor drive measurements
- Includes auto-discharge of capacitive voltage for added user protection
- Measures AC/DC voltage, DC millivolts, AC/DC milliamps, resistance, and continuity
- Includes capacitance, diode test, temperature, min/max, frequency measurements and insulation test smoothing reading
Specifications Fluke 1587 FC Insulation Tester Multimeter
AC Voltage Measurements | |
Range | 600 mV 6 V 60 V 600 V 1000 V |
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
50 to 60 Hz ±(% of Rdg + counts) | ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(2% + 3) |
60 to 5000 Hz ±(% of Rdg + counts) | ±(2% + 3) ±(2% + 3) ±(2% + 3) ±(2% + 3)1 ±(2% + 3)1 |
Low-Pass Filter Voltage | |
Range | 600 mV 6 V 60 V 600 V 1000 V |
Resolution | 0.1 mV 0.001 V 0.01 V 0.1 V 1 V |
50 to 60 Hz ±(% of Rdg + counts) | ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(2% + 3) |
60 to 400 Hz ±(% of Rdg + counts) | ±(2% + 3) – (6% – 3) ±(2% + 3) – (6% – 3) ±(2% + 3) – (6% – 3) ±(2% + 3) – (6% – 3) ±(2% + 3) – (6% – 3) |
DC Voltage Measurement | |
Range | 6 V DC 60 V DC 600 V DC 1000 V DC |
Resolution | 0.001 V 0.01 V 0.1 V 1 V |
Accuracy ±(% of Rdg + Counts) | ±(0.09% + 2) ±(0.09% + 2) ±(0.09% + 2) ±(0.09% + 2) |
Input Impedance | 10 MΩ (nominal), <100 pF |
Nominal Mode Rejection Ratio | >60 dB at 50 or 60 Hz |
Common Mode Rejection Ratio | >120 dB at DC, 50 or 60 Hz (1 k unbalance) |
DC Millivolts Measurement | |
Range | 600 mV DC |
Resolution | 0.1 mV |
Accuracy ±(% of Rdg + Counts) | ±(0.1 + 1) |
DC and AC Current Measurement | |
Range | 400 mA |
Resolution | 0.1 mA |
Accuracy ±(% of Rdg+Counts) | ±(1.5% + 2)1 |
Burden Voltage (Typical) | 2 mV/mA |
Range | 60 mA |
Resolution | 0.01 mA |
Accuracy ±(% of Rdg+Counts) | ±(1.5% + 2)1 |
Burden Voltage (Typical) | 2 mV/mA |
DC | |
Range | 400 mA |
Resolution | 0.1 mA |
Accuracy ±(% of Rdg+Counts) | ±(0.2% + 2) |
Burden Voltage (Typical) | 2 mV/mA |
Range | 60 mA |
Resolution | 0.01 mA |
Accuracy ±(% of Rdg+Counts) | ±(0.2% + 2) |
Burden Voltage (Typical) | 2 mV/mA |
Overload | 600 mA for 2 minutes maximum |
Fuse Protection for mA Input | 0.44 mA, 1000 V, IR 10 kA |
AC Conversion | Inputs are ac-coupled and calibrated to the RMS value of sine wave input |
Ohms Measurement | |
Range | 600 Ω 6 kΩ 60 kΩ 600 kΩ 6 MΩ 50 MΩ |
Resolution | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
Accuracy +(% of Rdg+Counts)1 | ±(0.9% + 2) ±(0.9% + 2) ±(0.9% + 2) ±(0.9% + 2) ±(0.9% + 2) ±(1.5% + 3) |
Overload Protection | 1000 RMS or DC |
Open Circuit Test Voltage | <8 V DC |
Short Circuit Current | <1.1 mA |
Diode Test | |
Diode Test Indication | Display voltage drop: 0.6 V at 1.0 mA nominal test current |
Accuracy | ±(2% + 3) |
Continuity Test | |
Continuity Indication | Continuous audible tone for test resistance below 25 Ω and off above 100 Ω Maximum reading: 1000 Ω |
Open Circuit Voltage | <8.0 V |
Short Circuit Current | 1.0 mA typical |
Overload Protection | 1000 V RMS |
Response Time | >1 m sec |
Frequency Measurement | |
Range | 99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHz |
Resolution | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz |
Accuracy ±(% of Rdg+Counts) | ±(0.1% + 1) ±(0.1% + 1) ±(0.1% + 1) ±(0.1% + 1) |
Frequency Counter Sensitivity | |
600.0 mV AC | V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 mV V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 150.0 mV DC Trigger Levels¹ to 20 kHz2: NA |
6.0 V | V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 1.0 V V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 1.5 V DC Trigger Levels¹ to 20 kHz2: -400.0 mV and 2.5 V |
60.0 V | V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 10.0 V V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 36.0 V DC Trigger Levels¹ to 20 kHz2: 1.2 V and 4.0 V |
600.0 V | V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 V V AC Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 V |
1000.0 V | V AC Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 300.0 V V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 V |
Capacitance | |
Range | 1000 nF 10.00 µF 100.0 µF 9999 µF |
Resolution | 1 nF 0.01 µF 0.1 µF 1 µF |
Accuracy ±(% of Rdg+Counts) | ±(1.2% + 2) ±(1.2% + 2) ±(1.2% ± 90 counts) ±(1.2% ± 90 counts) |
Temperature Measurement | |
Range | -40 to 998°F (-40 to 537°C) |
Resolution | 0.1°F (0.1°C) |
Accuracy ±(% of Rdg+Counts)1 | ±(1% + 10 counts) ±(1% + 18 counts) |
Insulation Specifications | |
Measurement Range | 0.01 MΩ to 2 GΩ |
Test Voltages | 50, 100, 250, 500, 1000 V |
Test Voltage Accuracy | 20%, 0% |
Short-Circuit Test Current | 1 mA nominal |
Auto Discharge | Discharge time <0.5 second for C=1 µF or less |
Live Circuit Detection | Inhibit test if terminal voltage >30 V prior to initialization of test |
Maximum Capacitive Load | Operable with up to 1 µF load |
Output Voltage | |
50 V (0% to +20%) | Display range: 0.01 to 6.00 MΩ Resolution: 0.01 MΩ Test current: 1 mA at 50 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) Display range: 6.0 to 50.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 50 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) |
100 V (0% to +20%) | Display range: 0.01 to 6.00 MΩ Resolution: 0.01 MΩ Test current: 1 mA at 100 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) Display range: 6.0 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 100 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) Display range: 6.0 to 100.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 100 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) |
250 V (0% to +20%) | Display range: 0.1 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 250 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 60 to 250 MΩ Resolution: 1 MΩ Test current: 1 mA at 250 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) |
500 V (0% to +20%) | Display range: 0.1 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 500 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 60 to 500 MΩ Resolution: 1 MΩ Test current: 1 mA at 250 kΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) |
1000 V (0% to +20%) | Display range: 0.1 to 60.0 MΩ Resolution: 0.1 MΩ Test current: 1 mA at 1 MΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 60 to 600 MΩ Resolution: 1 MΩ Test current: 1 mA at 1 MΩ Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 0.6 to 2.0 GΩ Resolution: 100 MΩ Test current: 1 mA at 1 MΩ Resistance accuracy ±(% of Rdg + Counts): ±(10% + 3 counts) |
Includes:
- Remote probe
- Test leads
- Alligator clips
- K-type thermocouple
- Soft case
- User documentation
Fluke 1587 FC – Datasheet
KARYA MANDIRI TECHINDO adalah Supplier Fluke 1587 FC Insulation Tester Multimeter dan juga menjual Brand Fluke. Lihat produk kami lainnya di sini JSI, SGI, SMG atau hubungi kami lewat Whatsapp 0821-3010-0456 atau via email [email protected].